Figure 17: Tracking Profile Window with Geofence Frequency Tab
Geofence Check Frequency: Sets the maximum time between position updates to
check if the device is in a geofence. If a valid GPS position is received before the next
check, the countdown to the next check is restarted.
o The AT command associated with this setting is ^GFCF.
Allowed GPS Acquisition Time: Sets the amount of time the geofence check attempts
to acquire a GPS position. If the SHOUT ns fails to acquire a position in the time
allowed, the geofence check is aborted and occurs at the next scheduled check or the
next time the GPS receiver has a valid position.
o The AT command associated with this setting is ^GFCF.
5.2.2.2.3
I
NTERVAL
The Interval tab provides four settings: Use Alternate Interval for Motion, Time Between Reports
(Standard and Motion), Time To Keep Trying (Standard and Motion), and Delayed First Report
(Standard and Motion), as shown in Figure 18.
Document Number: 451-01037-001D
T
AB
SHOUT ns/nsx User Guide Version D
51 of 91