 Only Once forces the SHOUT ns to send only once per report cycle regardless of
whether the tracking report was successfully transmitted or not.
 Until Next Report forces the SHOUT ns to retry sending a tracking report up to
the next reporting cycle if there is no successful transmission.
o Time To Keep Trying is specified in 5-second increments. It has a minimum value of
1.5 minutes and a maximum value of 21 minutes and 10 seconds.
o The AT command associated with this setting is ^TTKT (Standard) and ^TTKTA
(Motion).
 Delay First Report (Standard and Motion): When enabled, this setting prevents the
transmission of the first tracking report. This applies when tracking is turned on from
off or if there is a mode change. A mode change occurs when entering/leaving a
geofence and when emergency is enabled/disabled.
o An example of how this parameter might be useful is to avoid unwanted
transmissions that may accumulate airtime costs. If tracking mode is restarting
repeatedly because of frequent power cycling, reports are transmitted each time.
Enabling Delay First Report would delay that first report and reduce the airtime
usage.
o The AT command associated with this setting is ^DFR (Standard) and ^DFRA
(Motion).
5.2.2.3
A
DDITIONAL
This section covers the configuration tabs associated with the Other profile settings.
1. Select Options > Configure Window.
2. Select Other for the Profile Type at the top-left of the window.
Note: The Store Profile number has no effect for this profile type.
5.2.2.3.1
M
ISCELLANEOUS
The Miscellaneous tab shown in Figure 19 provides three settings: Remote Update Password,
Identifier in Reports, and Power-up Delay.
Document Number: 451-01037-001D
S
P
ETUP
ARAMETERS
T
AB
SHOUT ns/nsx User Guide Version D
53 of 91