As soon as a switch is plugged in make sure that the green power LEDs on the PS units are on.
Status LED and or Status Health LED
If either of these two LEDs is
Power supply unit:
If the LED on the PS unit is not lit or is red, check that the power cable is plugged into a working
outlet.
1. Check that the power cable has a voltage within the range of 100 - 240 volts AC.
2. Check that the air flow direction of the PS units are consistent with the Fan module air flow.
3. Remove and reinstall the power cable.
4. Remove and reinstall the PS unit.
The power LED for the switch shuts off:
1. Check that the there is adequate ventilation. Are the fan LEDs showing that the fans are all up
and running?
2. Make sure that there is nothing blocking the front or rear of the chassis and that the fan mod-
ules and ventilation holes are not blocked (especially dust over the holes).
3. If you find dust blocking the holes it is recommended to clean the fan unit and remove the
dust from the front and rear panels of the switch using a vacuum cleaner.
The green power LED for the fans does not come on:
1. Check that the Power LEDs are on.
2. Remove and reinstall the fan unit. Make sure the mating connector of the new unit is free of
any dirt and/or obstacles. See Section 6, "Switch Shut Down Procedure," on page 46.
3. Check that the mating connector pins are not bent.
Caution: Do not run the switch if the System Status LED for the Fans is Red!
The link LED for the connector does not come on:
1. Check that both ends of the cable are connected.
2. Check that the locks on the ends are secured.
3. Make sure that the latest firmware version is installed on all of the HCA cards and the switch.
4. If media adapters are used, check that the all connections are good, tight, and secure.
The activity LED does not come on:
When running IB check that the Subnet Manager has been started.
The switch is off:
1. Unplug the switch.
2. Wait 5 minutes.
3. Plug in the switch.
unplug the switch and call your Mellanox representative.