4. If the switch does not come on, check the power supplies.
5. If the switch comes on, Use the MLNX-OS™ management CLI to determine the cause of the
Shutdown.
6. Check the temperature.
7. Check the Fan status.
The switch is not working and unresponsive:
1. Reset the switch.
If resetting the switch does not work:
2. Unplug the switch.
3. Wait 5 minutes.
4. Plug in the switch.
5. If the switch does not come on, check the power supplies.
6. If the switch comes on, use the MLNX-OS management CLI to determine the cause of the
shutdown.
The last software update did not succeed:
1. Connect the RS232 connector (CONSOLE) to a laptop.
2. Push the reset button on the switch or management module.
3. You will have ~ 5 seconds to stop the U-Boot by pressing Control-B.
4. Choose the image to upload. Only use image 1 or image 2.
U-Boot 2009.01-mlnx1.4 (May 12 2010 - 14:08:15)
CPU:
Board: Mellanox PPC460EX Board
FDEF:
I2C:
DRAM:
FLASH: 16 MB
NAND:
PCI:
PCIE0: link is not up.
52
Mellanox Technologies
AMCC PowerPC 460EX Rev. A at 1000 MHz (PLB=200, OPB=100,
EBC=100 MHz)
Security/Kasumi support
Bootstrap Option H - Boot ROM Location I2C (Addr 0x52)
Internal PCI arbiter disabled
32 kB I-Cache 32 kB D-Cache
No
ready
2 GB (ECC enabled, 400 MHz, CL3)
1024 MiB
Bus Dev VenId DevId Class Int
Troubleshooting