KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUSTOMER'S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY.
This icon indicates information that is helpful to the user. This icon indicates a situation that can potentially cause damage to hardware or soft- ware. BEWARE! This icon indicates a situation that can potentially cause personal injury or damage to hardware or software. Mellanox Technologies...
InfiniBand fab- rics, managed as a single unified network infrastructure. The TX6000 and TX6100 systems, which implement long-haul InfiniBand, can transfer data up to distances of 1km and 10km, respectively.
Introduction to Mellanox TX6000/TX6100 Long Haul Systems Speed and Switching Table 3 describes maximum throughput and interface speed per system model. Table 3 - Speed and Switching Capabilities 10GbE* SFP+ System Model 40/56GbE QSFP+ Interfaces Throughput Interfaces TX6000 16 FDR10 QSFP+ uplink...
• Fabric Inspector • Embedded Subnet Manager (SM) 1.4.3 Long Haul Features 1.4.3.1 TX6000 • 16 Long haul (40Gb/s) ports in a 1U system • Up to 640Gb/s long-haul aggregate data • 16 Downlink (56Gb/s) VPI ports • Compliant with Mellanox LR4 and SR4E QSFP+ 40Gb/s transceivers 1.4.3.2 TX6100...
(Romanian),” on page 69. For Safety Warnings in Croatian see Section E.9, “Sigurnosna upozorenja za instaliranje (Croa- tian),” on page 73. For Safety Warnings in Italian see Section E.10, “Avvertenze di sicurezza per l’installazione (italiano),” on page 76. Mellanox Technologies...
Table 6 provides an air flow label color legend and respective OPN designations, Table 6 - Air Flow Label Legend Label Direction Description Designation Connector side inlet to power side outlet. Red labels are placed on the power inlet side. Mellanox Technologies...
Blue labels are placed on the power inlet side. Figure 2: Air Flow Direction Marking - Connector Side Inlet to Power Side Outlet Figure 3: Air Flow Direction Marketing - Power Side Inlet to Connector Side Outlet Mellanox Technologies...
Before installing your new system, unpack the system, and check, against the parts list below, that all the parts have been sent. Check the parts for visible damage that may have occurred dur- ing shipping. The TX6000/TX6100 package content is as follows: • 1 – System • 1 – Rail kit •...
If using a torque screwdriver to tighten the screws, set it to 0.85Nm. Clip the caged nuts into the holes in the rack on the side of the rack you will be sliding the sys- Step 3. tem into. Mellanox Technologies...
Figure 7: Slide the Rail into the Rail Slide This side of the rail kit goes on the side of the rack you will slide the system into. This is the same side of the system that will be next to the vertical support. Mellanox Technologies...
Figure 8: Installing the Slides Slide the system into the rails. Step 6. Place the system and screw the bolts into the nuts. Tighten the bolts to 9.2 Nm or 81.5 pound Step 7. inches. Mellanox Technologies...
Test the ground using an Ohm meter. Some national and/or local codes may require IT components to be bonded and exter- nally grounded (not including the power cord ground). You must follow all national and local codes when installing this equipment. Mellanox Technologies...
When using this feature you should login into the MLNX-OS® CLI and configure the individual ports to be ‘split-2’ or ‘split-4’. Mellanox Technologies...
Step 4. with normal operation, as shown in Figure 13 below. For more information, refer to “LEDs” on page 30. Figure 13: System Status LEDs 5 Minutes After Power On System with 1 PSU System with 2 PSUs Mellanox Technologies...
PC with the settings described in Table 8. Once you perform that, you should get the CLI prompt of the system. Table 8 - Serial Terminal Program Configuration Setting Parameter Baud Rate 9600 Data bits Stop bits Parity None Mellanox Technologies...
Step 4: Enable IPv6 auto-config This turns on auto-configuration of the IPv6 addresses. This is (SLAAC) on mgmt0 interface? unsuitable for DHCPv6. [no] Step 5: Enable DHCPv6 on To enable DHCPv6 on the MGMT0 interface. mgmt0 interface? [no] Mellanox Technologies...
To change an answer, enter the step number to return to. Otherwise hit <enter> to save changes and exit. Choice: Configuration changes saved. To return to the wizard from the CLI, enter the “configuration jump-start” command from configure mode. Launching CLI... > Mellanox Technologies...
Set up an Ethernet connection between the system and a local network machine using a stan- Step 1. dard RJ45 connector. Start a remote secured shell (SSH) using the command: “ssh -l <username> <IP_address>”, Step 2. # ssh -l <username> <ip address> Mellanox Technologies...
Grasping the handle with your right hand, push the latch release with your thumb while pulling Step 2. the handle outward. As the power supply unit unseats, the power supply unit status LEDs will turn off. Remove the power supply unit. Step 3. Mellanox Technologies...
Insert the other end of the power cord into an outlet of the correct voltage. Step 5. The green power supply unit indicator should light. If not, repeat the whole procedure to extract the power supply unit and re-insert it. Mellanox Technologies...
These two latches must be pushed towards each other at the same time while the module is pulled out. Latch release Push here To insert a FAN Unit: Make sure the mating connector of the new unit is free of any dirt and/or obstacles. Step 1. Mellanox Technologies...
Page 32
The green Fan Status LED should light. If not, extract the fan unit and reinsert it. After system two unsuccessful attempts to install the fan unit, power off the before attempt- ing any system debug. Mellanox Technologies...
Refer to Section 2.8.1 to view the full pro- cedure. 3.1.4 Management The RJ45 Ethernet port labeled “MGT” provides access for remote management. The man- agement port is configured with auto-negotiation capabilities by default (100MbE to 1000GbE). Mellanox Technologies...
DO NOT use a sharp pointed object such as a needle or a push pin for pressing the Reset button. Use a flat object to push the reset button. To reset the system and the CPU of its management board, perform the following: Mellanox Technologies...
Power supply #2 Shows the health of the left side power supply unit Green Bad Port LED lights up when a symbol error is detected on one of the ports. Unit Identifier LED Lights up on command through the CLI Mellanox Technologies...
Mellanox representa- tive for assistance. The system has no power. Check the power source and cable. 3.2.2.2 Fan Status LED All fans must be operating while the power supply is plugged in. Mellanox Technologies...
Check that the fan unit is properly and completely inserted. power. Risk of Electric Shock! With the fan module removed power pins are accessible within the module cavity. DO NOT insert tools or body parts into the fan module cavity. Mellanox Technologies...
In case there is an FRU, the module should be replaced. Otherwise, the sys- tem should be replaced. There is no power to the system, the unit is Check power source or replace the cable. receiving no power. Mellanox Technologies...
Solid Orange Physical link is up. Wait for the Logical link to raise. Check that the SM is up. Flashing Orange A problem with the physical link. Check that the SM is up. Mellanox Technologies...
Page 40
When a logical connection is made the LED will change to green. When data is being transferred the light will blink green. Mellanox Technologies...
Inventory Pull-out Tab The system’s inventory parameters (such as serial number, part number, GUID and MAC address) can be extracted from the Inventory pull-out tab on the lower right side of the front panel. Figure 23: Pull-out Tab Mellanox Technologies...
SwitchX®-2 based managed systems. MLNX-OS® includes a CLI, WebUI, SNMP, system management software and IB management software (OpenSM). The Ethernet ports for remote management connect to Ethernet systems. These sys- tems must be configured to 100Mb/1 Gb auto-negotiation. Mellanox Technologies...
This state is indicative of a problem with the PSU. • Check/replace the power cable. • Replace the PSU if needed. The activity LED does not Make sure that there is an SM running in the fabric. light up (InfiniBand): Mellanox Technologies...
Specifications TX6000 System Table 18 - TX6000 Specifications Feature Value 1.71” H x 16.85” W x24.75” D 43.6mm X 428mm X 629.2 mm Mechanical Size: Mounting: 19” rack mount Weight: 8.95kg 1 PSU 9.69kg 2 PSUs Speed: up to FDR10 in the uplink ports and FDR in the downlink ports.
MSX60-SKIT Rack installation kit for MSX60XX and MSX10XX series short/standard depth 1U systems to be mounted into standard depth racks HAR000028 Harness RS232 2M cable – DB9 to RJ-45 (for managed switches only) ACC000501 Power cord Type C13-C14 Mellanox Technologies...
When the SwitchX® device crosses this temperature, the firmware will automatically shut down the device. 3.Emergency – 130C In case the firmware fails to shut down the SwitchX® device upon crossing the Critical thresh- old, the SwitchX® device will auto-shutdown upon crossing the Emergency (130C) threshold. Mellanox Technologies...
Vcc Tx +3.3 V Power supply transmitter Vcc 1 +3.3 V Power Supply LPMode Low Power Mode Ground Tx3p Transmitter Non-Inverted Data Input Tx3n Transmitter Inverted Data Input Ground Tx1p Transmitter Non-Inverted Data Input Tx1n Transmitter Inverted Data Input Mellanox Technologies...
(EEE) should be collected separately and not disposed of with regular household waste. Dispose of this product and all of its parts in a responsible and environmentally friendly way. Follow the instructions found at http://www.mellanox.com/page/dismantling_procedures for proper disassembly and disposal of the switch, according to the WEEE directive. Mellanox Technologies...
45°C (113°F). Moreover, to guarantee proper , allow at least 8cm (3 inches) of clearance around the ventilation openings. 5. Stacking the Chassis The chassis should not be stacked on any other equipment. If the chassis falls, it can cause bodily injury and equipment damage. Mellanox Technologies...
Page 54
11. Equipment Installation This equipment should be installed, replaced, and/or serviced only by trained and qual- ified personnel. 12. Equipment Disposal Disposal of this equipment should be in accordance to all national laws and regula- tions. Mellanox Technologies...
Page 55
Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL certified type DP-1 or DP-2. (Note- when residing in non LPS circuit) 19. Overcurrent Protection: A readily accessible Listed branch circuit overcurrent protective device rated 20 A must be incorporated in the building wiring. Mellanox Technologies...
This unit is intended for connection to a TN power system and an IT power system of Norway only. 安裝安全性警告 (Chinese) 1. 安裝指示 本設備附有備援電源供應器或在適當位置配有空白蓋板。 2. 因重量導致的人身受傷 為了安全起見,請安排足夠的人員以合力抬起本產品。 <40 lbs 70 - 121 lbs >121 lbs 40 - 70 lbs <18 kgs 32 - 55 kgs >55 kgs 18 - 32 kgs Mellanox Technologies...
6. Connexion de l'alimentation redondante : danger d'électrocution Ce produit est équipé d'une alimentation redondante ou d'un cache si elle est absente. Dans ce dernier cas, ne pas faire fonctionner le produit si le cache est retiré ou mal fixé. Mellanox Technologies...
Page 62
12. Mise au rebut de l'équipement La mise au rebut de cet équipement doit se faire conformément à toutes les lois et réglementations nationales. 13. Codes électriques locaux et nationaux Cet équipement doit être installé conformément aux codes électriques locaux et nation- aux. Mellanox Technologies...
Page 63
Cet appareil doit être installé conformément à la version la plus récente des codes élec- trique nationaux. En Amérique du Nord, l'équipement doit être installé en respectant les exigences de l'US National Electrical Code et du Code canadien de l'électricité. Mellanox Technologies...
2. Verletzungsgefahr wegen des Gewichts Um das Produkt sicher anzuheben, genügend Personen einsetzen. <40 lbs 70 - 121 lbs >121 lbs 40 - 70 lbs <18 kgs 32 - 55 kgs >55 kgs 18 - 32 kgs Mellanox Technologies...
Page 65
9. Rack-Montage und Wartung Wenn dieses Produkt in einem Rack montiert oder gewartet wird, sind besondere Vor- sichtsmaßnahmen zu ergreifen, um die Stabilität des Systems zu gewährleisten. Im Allgemeinen sollten Sie das Gestell von unten nach oben mit Geräten füllen. Mellanox Technologies...
Page 66
3 - Leiter, mindestens 0,75 mm2 Draht, bewertet mit 300 V, mit einem PVC-Mantel isoliert. Das Kabel muss eine angespritztem Stecker bewertet bei 250 V, 10 A. " 16. Hoher Ableitstrom WARNUNG: Hohe Ableitstrom; Earth Verbindung, bevor Sie die Verbindung von wesentlicher Bedeutung werden. Mellanox Technologies...
Dieses Produkt und alle seine Teile in verantwortungsvoller und umweltfreundlicher Art und Weise entsorgen. Advertencias de seguridad de instalación (Spanish) 1. Instrucciones de instalación Antes de conectar el equipo a la fuente de alimentación, leer todas las instrucciones de instalación. Mellanox Technologies...
Page 68
7. Tomas de alimentación múltiples Riesgo de descarga eléctrica y peligro de corriente. Todas las fuentes de alimentación son independientes. Desconecte todas las fuentes de alimentación, para asegurar que no haya corriente alguna dentro de la plataforma de conmutación. Mellanox Technologies...
Page 69
Este dispositivo se debe instalar conforme a la versión más reciente de los códigos eléctricos nacionales del país en cuestión. En América del Norte, el equipo se debe instalar de acuerdo con las disposiciones vigentes del Código Eléctrico Nacional de los EE.UU. y del Código Eléctrico de Canadá. Mellanox Technologies...
Page 70
La finalidad de los rieles no es deslizar la unidad hacia afuera del bastidor. Sirven solo para la instalación permanente en el lugar de destino final, no para fines de servicio o mantenimiento Mellanox Technologies...
НЕ вставлять инструменты или части тела в углубление вентиляторного модуля. 4. Перегрев Не эксплуатировать это оборудование в помещении с температурой окружающей среды, превышающей максимально рекомендуемое значение: 45 °C (113 °F). Более того, для надлежащей вентиляции следует обеспечить зазор вокруг вентиляционных отверстий не менее 8 см (3 дюйма). Mellanox Technologies...
Page 72
10. Установка или обслуживание в стойке При установке или обслуживании этого изделия в стойке следует обеспечить устойчивость системы. Как правило, стойка заполняется оборудованием снизу вверх. 11. Установка оборудования Устанавливать, заменять и/или обслуживать это оборудование должен только подготовленный и квалифицированный персонал. Mellanox Technologies...
Page 73
сечением жилы не менее 1,0 мм², рассчитанного на номинальное напряжение 300 В, с ПВХ оболочкой. Шнур должен иметь литую вилку, рассчитанную на 250 В, 10 А. 17. Высокий ток утечки Осторожно! Высокий ток утечки. Заземлить перед подключением к электропитанию. Mellanox Technologies...
электронного оборудования должны собираться и утилизироваться отдельно от обычных бытовых отходов. Следует утилизировать это изделие и все его части ответственным и экологически безопасным способом. Avertismente privind siguranţa la instalare (Romanian) 1. Instrucţiuni de instalare Citiţi toate instrucţiunile de instalare înainte de a conecta Mellanox Technologies...
Page 75
îndepărtat sau nu este fixat în mod sigur. 7. Multiple mufe electrice Risc de şoc electric şi pericol electric. Toate aparatele cu alimentare de la reţea sunt independente. Deconectaţi toate sursele de alimentare cu energie pentru a asigura decuplarea în inte- riorul platformei de comutare. Mellanox Technologies...
Page 76
Acest dispozitiv trebuie să fie instalat în conformitate cu ultima versiune a codurilor electrice naţionale ale ţării în cauză. Pentru America de Nord, echipamentul trebuie să fie instalat conform cerințelor aplicabile din Codul electric naţional al SUA şi Codul electric canadian. Mellanox Technologies...
Page 77
Atenţie: Echipamentul montat pe o linie de alunecare/şină nu va fi utilizat ca raft sau spaţiu de lucru. Scopul şinelor nu este de a glisa unitatea de pe rack. Acestea sunt des- tinate instalării permanente numai la punctul final de oprire şi nu vor fi folosite pentru depanare şi întreţinere Mellanox Technologies...
45°C (113°F). Osim toga, kako bi se osig- urao odgovarajući protok zraka, omogućite najmanje 8 cm (3 inča) razmaka oko otvora ventilatora. 5. Slaganje kućišta Kućište se ne bi trebalo slagati na drugu opremu. Ako kućište padne, može izazvati tjelesne ozljede i oštećenje opreme. Mellanox Technologies...
Page 79
11. Instaliranje opreme Ovu bi opremu trebalo instalirati, zamjenjivati i/ili servisirati samo obučeno i kvalifici- rano osoblje. 12. Odlaganje opreme Odlaganje opreme trebalo bi se vršiti sukladno nacionalnim zakonima i propisima. Mellanox Technologies...
Page 80
Upozorenje: Veliko curenje struje; Prije spajanja napajanja nužno je spojiti uzem- ljenje. 18. Instalacijski kodovi Ovaj se uređaj mora instalirati sukladno najnovijoj verziji nacionalnih električnih kodova države. U Sjevernoj Americi oprema se mora instalirati sukladno važećim zahtjevima navedenim u US National Electrical Code i Canadian Electrical Code. Mellanox Technologies...
Ovaj je uređaj namijenjen samo za spajanje na električni sustav s TN uzemljenjem i na električni sustav s IT uzemljenjem države Norveške. E.10 Avvertenze di sicurezza per l’installazione (italiano) 1. Istruzioni di installazione Leggere tutte le istruzioni di installazione prima di collegare l’apparecchiatura all’alimentazione. Mellanox Technologies...
Page 82
7. Prese di alimentazione multiple Rischio e pericolo di scosse elettriche. Gli alimentatori sono tutti indipendenti. Scollegare tutti gli alimentatori per assicurarsi che il commutatore non sia sotto tensione Mellanox Technologies...
Page 83
Questo dispositivo va installato in conformità con l’ultima versione dei codici elettrici nazionali del Paese. Per il Nord America, l’apparecchiatura va installata in conformità con i requisiti applicabili del “codice elettrico nazionale USA” e del “codice elettrico canadese”. Mellanox Technologies...
Page 84
Attenzione: un’apparecchiatura scorrevole o montata su binari non va utilizzata come scaffale o piano di lavoro. I binari non sono progettati per far scorrere e allontanare l’unità dal rack. Essi sono destinati all’installazione permanente solo nel luogo di lavoro e non vengono utilizzati per assistenza e manutenzione Mellanox Technologies...
Page 85
Secondo la direttiva RAEE 2002/96/EC, tutti i rifiuti da apparecchiature elettriche ed elettroniche (RAEE) vanno raccolti separatamente e non smaltiti nei normali rifiuti domestici. Smaltire questo prodotto e tutte le sue parti in modo responsabile e rispettoso dell’ambiente Mellanox Technologies...
45 °C (113 °F). Ayrıca, düzgün hava akışı sağlamak için havalandırma deliklerinin etrafında en az 8 cm (3 inç) açıklık bırakılmalıdır. 5. Şasi İstif Şasinin diğer herhangi bir ekipmanın üzerine istiflenmemesi gerekir. Şasi düşerse, fiziksel yaralanmalara ve ekipmanda hasara neden olabilir. Mellanox Technologies...
Page 87
özel önlemler alınmalıdır. Genelde, ekipmanları iskeleye aşağıdan yukarı doğru doldurmanız gerekir. 11. Ekipman Montajı Ekipmanın yalnızca eğitimli ve nitelikli personel tarafından monte edilmesi, değiştirilmesi ve/veya bakımının yapılması gerekir. 12. Ekipmanın Atılması Bu ekipmanın imhasında tüm ulusal yasalara ve düzenlemelere uyulması gerekir. Mellanox Technologies...
Page 88
RS232 ünitesini ve Ethernet Arabirimlerini bağlayacak olan kabloların UL onaylı DP-1 veya DP-2 tipi olması gerekir. (Not- LPS olmayan devreye aitse) Aşırı Akım Koruması: Kolayca erişilebilecek 20 V Kayıtlı devre parçası aşırı akım koruma cihazının bina elektrik şebekesinde kurulu olması gerekir. Mellanox Technologies...