Technical description

Installation position

7.1
76
───
Observe the maintenance intervals and mounting positions
Carry out maintenance at regular intervals.
In the horizontal mounting position IM V3, liquid which has been left
on the flange for a longer period can penetrate the motor through
capillary action. In mounting position IM V1 liquid can escape.
If you do not observe the maintenance intervals, the motor may
overheat depending on the mounting position. Ingress and leakage
of liquids may damage the motor.
The standard installation position of the gear units is the motor at-
tachment "M". You can use the gear units in any other installation
position.