The following are available for the image quality.
SFA/SFB: Top quality (SUPER FINE)
FQA/FQB: High quality (FINE)
NQA/NQB: Standard quality (NORMAL)
EXA/EXB: Low quality (EXTENDED)
**A is suitable for less dynamic images.
**B is suitable for more dynamic images.
8 Event REC
Perform the recording rate (REC Rate) and the image quali-
ty (Quality) for event recording (recording to be performed
at event occurrence (motion detection, video loss, terminal/
command alarm and terminal alarm)).
The following are available for "REC Rate" (recording rate).
OFF/2 ips/3 ips/5 ips/6 ips/7.5 ips/10 ips/15 ips/30 ips/
60 ips/120 ips
Note: The camera channel number selected for "REC
Camera" will be displayed next to the selected record-
ing rate.
Note: The available recording rate differs depending on the
selected solution.
Resolution
FRAME 3D ON/FRAME 3D OFF
FIELD
SIF
The following are available for "Quality" (image quality).
SFA/SFB: Top quality (SUPER FINE)
FQA/FQB: High quality (FINE)
NQA/NQB: Standard quality (NORMAL)
EXA/EXB: Low quality (EXTENDED)
**A is suitable for less dynamic images.
**B is suitable for more dynamic images.
The following are available for "Time" (recording duration).
1 s - 10 s (in 1 second intervals)/20 s/30 s/1 min - 10 min
(in 1 minute intervals)/20 min/30 min/ 40 min/ 50 min/
60 min
MANUAL: Recording duration differs depending on the
event type as follows;
When a motion is detected: Recording will be per-
formed for 8 seconds
When a video loss has occurred: Recording will be
performed while the video signal is lost.
When a terminal alarm has occurred: Recording will
be performed while the alarm signal is being sup-
plied.
When a command alarm has occurred: Recording will
be performed for 8 seconds.
CONTINUE: Record until the ALARM RESET button is
pressed.
98
Maximum recording rate
30 ips
60 ips
120 ips
Note: When "MANUAL" is selected for "Time" (recording
duration), recording will be performed for at least 8
seconds at an event occurrence as long as the
alarm is not canceled.
The following are available for "Operation Mode" (event
action mode). Refer to page 49 for further information about
each event action mode.
ACT DET (Activity Detection Mode): Performs only
recording, writing an event log and camera movement
to a preset position at an event occurrence. Other event
actions will not be performed.
ALARM (Alarm Mode): Performs every event action
according to the settings.
OFF: Performs only recording of the event log. Other event
actions will not be performed.
8 Event Setup
Perform the settings for the alarm output duration and the
buzzer sound duration for each event type (motion detec-
tion, video loss, command alarm and terminal alarm).
[Screenshot 1]
Start operation from the "REC & Event" menu.
SETUP MENU
Quick
I
Display
REC Type
I
REC Camera
REC & Event
I
Resolution
I
Network
Manual REC
REC Rate
Quality
I
Event REC
REC Rate
Quality
Time
Operation Mode
I
Event Setup
I
Power ON Manual REC
I
Advanced Menu
VMD Setup
z Move the cursor to "Event Setup" using the arrows but-
ton (C D) and press the SET button.
[Screenshot 2]
The "Event Setup" pop-up menu will be displayed.
SETUP MENU
Quick
I
Display
REC Type
I
Event Setup
REC Camera
REC & Event
I
VMD
I
Resolution
Alarm Output
I
Network
Manual REC
Buzzer
REC Rate
I
Video Loss
Quality
Alarm Output
I
Event REC
Buzzer
I
Terminal/Command Alarm
REC Rate
Alarm Output
Quality
Buzzer
Time
Operation Mode
I
Event Setup
I
Power ON Manual REC
I
Advanced Menu
VMD Setup
x Move the cursor to the item to be set using the arrows
button (C D), and rotate the jog dial to select the para-
meter.
The following are available for "Alarm Output" (alarm
output duration).
When OFF is selected, the alarm output will not be sup-
plied.
(s: second, min: minute)
OFF: No alarm output is supplied.
LIVE
QUICK
SETUP
FIELD
30ips / 16CH
FQB
30ips / 16CH
FQB
30s
ALARM
SETUP
OFF
SETUP
LIVE
QUICK
SETUP
OFF
FIELD
OFF
30ips / 16CH
--
FQB
2s
30ips / 16CH
2s
2s
FQB
30s
ALARM
SETUP
OFF
SETUP