PROGRAM MONITOR

Program Monitor
Program Num in TS: This field displays the current program being decoded by the decoder. Range
for this value can be from 0 to 65535.
PMT PID: This parameter returns the PID for the PMT, for the program being decoded. Range for this
value can be from 0 to 8191. When in Manual PID Selection Mode no value will be displayed.
PCR PID: This parameter returns the PID which has the PCR information for the program being
decoded. Range for this value can be from 0 to 8191. When in Manual PID Selection Mode no value
will be displayed.
Num Video Streams: This parameter returns the number of Video Streams in the program which are
being decoded. Range for this value can be from 0 to 100. When in Manual PID Selection Mode no
value will be displayed. Also, it is assumed there is only one video stream in one program.
Num Audio Streams: This parameter returns the number of Audio Streams in the program which are
being decoded. Range for this value can be from 0 to 100. When in Manual PID Selection Mode no
value will be displayed.
Program Video Monitor
Video PID Num: This field displays the PID which carries the PES for Video. Range for this value can
be from 0 to 8191.
Video Bit Rate: This field displays the bit rate for the video elementary stream.