2430RX-J2K-IP
JPEG2000 to HDMI Converter User Manual
Auto Program Select Mode: This control allows the user to set how the decoder will select a
program for decoding when Program Tuning Mode is set to auto.
First Program in PAT: select audio PIDs from first program will be chosen.
Lowest Program Num: select audio PIDs from lowest program will be used.
Specific Program Select: will pick audio PIDs from specific program, specified by Program
Number Select control, for decoding.
Program Number Select: This parameter allows the user to select the program which will be
decoded. This control is applicable only when the Program Tuning Mode is set to Auto PID Select,
value for this range can be set from 0 to 65535.
PID Control
Note: 0, 1 and 8191 are reserved PID's in MPEG, so these values are not
included.
Video PID Select: This control allows the user to select the Video PID that will be decoded. This
control is only applicable when the Program Tuning Mode is set to Manual PID Select. Range for
these values can be set from 2 to 8190.
Audio PID Select 1 – 4: This control allows the user to select up to four Audio PID's which the
decoder will decode and embed into the output video. This control is only applicable when the
Program Tuning Mode is set to manual PID select.
PCR PID Select: This parameter allows the user to select the PID for incoming PCR clock. This
control is only applicable when the Program Tuning Mode is set to Manual PID Select. Range for
these values can be set from 2 to 8190.
VANC PID Select: This control allows the user to select the VANC PID which will be decoded. This
control is only applicable when the Program Tuning Mode is set to Manual PID Select. Range for
these values can be set from 2 to 8190.
PID Configuration: This parameter configures the method in which PIDs are set. It can be user
defined or pre-assigned, in which case all the PID controls will be greyed out.
Decoder Control
Decoder Up Time: This controls returns a string representation of the time the decoder was last
restarted. It is represented similar to 'xxxx days yy hrs zz min aa sec'. Internally, it is a 31 bit
unsigned integer, reflecting seconds which will provide for up to 3100 days of operation before it
wraps around.
Load Factory Config: Part of the Input Control table, this variable allows the SNMP Manager to
revert the decoder configuration to a known factory recommended setting. The manager should read
the variable prior to setting, to ensure it is in the 'ready' state. Writing the 'load' command will cause
the decoder to cease current operations and sources and load the factory default configuration
settings. This will NOT include IP interface settings, to ensure network contact is maintained. When
the variable returns to the 'ready' state, the operation is complete. The operator can then manually
refresh configuration displays.