5.5
Setting of terminator
When using the conveyor synchronization function, setting of the terminator is
necessary because the encoder cable can be connected not only individually, but
in a row as shown in Fig. 5.13 below and the conveyor position can be identified
by each controller. The terminator setting is established by ON/OFF of SW4 (4
poles) equipped on the option (X8HL) printed board. A pair of SW4–1 and
SW4–2 can be used for CH1. Likewise, a pair of SW4–3 and SW4–4 can serve
for CH2. (See Table 5.1 below.)
All of four (4) poles of SW4 of the option (X8HL) printed board are
factory-set to "ON" before shipment.
Table 5.1 SW4 setting (When the SW is set ON, the terminator is set.)
SW No.
SW4–1
SW4–2
SW4–3
SW4–4
Controller 1
Encoder
INSTRUCTION MANUAL CONVEYOR SYNCHRONIZATION FUNCTION
Signal name
CH1A
ON/OFF
CH1B
ON/OFF
CH2A
ON/OFF
CH2B
ON/OFF
Fig. 5.13 Continuous connection of encoder
Setting
Terminator setting switch for
CH1 phase A data.
Terminator setting switch for
CH1 phase B data.
Terminator setting switch for
CH2 phase A data.
Terminator setting switch for
CH2 phase B data.
Controller 2
– 42 –
Remarks
Controller N