3.6

[8] Travel Distance per Pulse of Encoder

This parameter specifies the conveyor travel distance (µm) per one (1) pulse of
the encoder set to the conveyor.
Data format
Data unit
Example of value
If the total number of encoder pulses is ∆P (pulse) when the conveyor moves by
∆L (mm), the conveyor travel distance per one (1) pulse of the encoder α (µm) can
be calculated from the following equation.
α = (∆L / ∆P) * 1000
The total number of encoder pulses (∆P) can be obtained in the following manner.
(1) Press the desired function key (<F1: MES1> or <F2: MES2>) for the channel
(CH) you wish to measure, using the cursor.
C O N V
U T I L I T Y
C o n v
C o n v
C o n v
E n c
M e s
M e s
M E S 1
When you wish to count the number of pulses of CH1, press <MES1>.
INSTRUCTION MANUAL CONVEYOR SYNCHRONIZATION FUNCTION
:
Real number
:
µm
:
0
F o r m
:
V e l o c
: - * * * * . * * *
S t a t u s :
P u l s e
:
P u l s e
:
T r i p
: - * * * * . * * *
M E S 2
– 15 –
< C H 1 >
L I N E A R
- * * * . * * * *
0
3 2 7 6 7
6 3 2 4 1 7
- * * * . * * * *
< C H 2 >
A R C ( + )
0
3 2 7 6 7
0