IN120 / IN220 Mortise Lock
IN220 (PoE) Installation Wiring (Continued)
Supplied by CI
B-Splice
Crimp Connector
RJ45-M
Ceiling
24AWG
Stranded
Drain
Wire for
Earth
Ground in
15' Frame
Harness
Frame-Side
Harness
Assembly
(15' length)
Cable drain wire
concealed in
shrink tubing
Molex-F
Molex-M
A
Certified Integrator (CI) supplies and terminates
the B-Splice connector and the
male RJ45 connector from harness to
end user provided facility cable
To building or electrical ground
RJ45-F Jack
Cable: Cat 5e or higher
24 AWG
Cable
: Cat 5e (or higher),
26 AWG stranded,
100ohm
C
Molex-F Molex-M
B
Ring Terminal
Secured to Lock
Mounting Plate
Wiring to TIA/EIA 568-B Standard
Patch Cable
Patch Panel to
PoE Switch
D
PoE
Lock
RJ45-M
Ground
1-800-810-WIRE • www.sargentlock.com • A8151H
Supplied by End User
PoE Switch
PoE Switch is
Terminated to
Earth Ground
Patch Panel
Drain Wire Terminated on Rack
Approved Software
Notes:
• Connectors go on only
one way. They cannot
be placed in an incorrect
position.
• Do not force and do not
offset connectors
• Be sure they are
completely seated (flush)
• PoE power source
cannot be connected to
a receptacle controlled
by a switch
9