9 Preparation of Connectors
CAUTION - Do not touch or allow debris to enter connector contacts.
Ensure connectors are covered with silicone dielectric compound
• Snip end of packet to dispense grease
• Ensure all connector pins and contacts (Fig. 9) are
covered - do not overfill or over-apply**
*Supplied tube contains 5 grams of silicone dielectric compound (grease)
**Evenly distribute grease, wiping away excess; full application requires
approximately 2.5 grams
IMPORTANT: Do not run wires through bottom hole in plate (Fig. 9) - it will
damage wires and the controller connector. Route wires around
flange, do not route wires through the flange hole (Fig. 9 ).
10 Installation of Connectors
Secure the following connectors (Fig. 10A, B):
A. Secure the 4-pin DPS connector.
B. Secure the 10-pin lock body assembly connector.
Secure Mounting Plate
Tuck excess cable into wire hole on inside of door
Secure the mounting assembly while ensuring proper
alignment of outside reader and fully tighten the (2)
through-bolts on the inside of the door to secure the
reader and plate to the door
C. Secure the 24-pin card reader connector (Fig. 10A, B)
D. Ensure all openings on back of secured reader connector are
covered completely with grease (Fig. 10B).
22
1-800-810-WIRE • www.sargentlock.com • A8151H
Important Note: Before you secure the connectors
SILICONE DIELECTRIC
COMPOUND
IN120 / IN220 Mortise Lock
(grease)*
FILL
FILL
Fig. 9
Reader
(24-pin)
Board-to-Board
Connector
FILL
Fig. 10B
APPLY
FILL
FILL
NO WIRES
THRU THIS
OPENING
C
A
B
Fig. 10A