replacing a power supply
1. Remove the front bezel from the system and remove the defective power supply if you have
not already done so.
2. Open the power supply release lever and slide the power supply into place.
3. Push in on the power supply release lever to lock the retaining clip in place.
4. Replace the front bezel.
hard drives
The zx6000 and rx2600 systems can support up to three hot-pluggable, Low-Voltage Differential
(LVD) hard disk drives. These hard disk drives are 3.5-inch form factor, 10K and 15K RPM
devices that connect to Ultra 320 Wide LVD (Low Voltage Differential) SCSI interfaces on the
disk bay backplane.
There is a significant difference between the terms hot-pluggable and hot-swappable:
Hot swapping happens at the device level; that is, a hot-swappable device manages
insertion/removal on its own without assistance from operating system commands.
The hot-plug process allows you to replace a defective disk drive in a high-availability
system while it is running.
CAUTION: The disk drives in the zx6000 and rx2600 are not hot-swappable; they are merely hot-pluggable.
A manual software procedure must be done in order to safely remove or insert disk drives while the system is
running. To avoid damage to the hard drives:
See the documentation provided with the drive for additional details on inserting/removing a disk drive.
See your OS documentation for instructions on preparing the OS for inserting/removing a hard drive.
operations and maintenance guide
Installing or Replacing Parts and Accessories