Install Canopy Fixture (0-10 V And Dali Variants) - ETC Irideon WLZ User Manual

Hide thumbs Also See for Irideon WLZ:
Table of Contents

Advertisement

Install Canopy Fixture (0–10 V and DALI
Variants)
Note:
0–10 V range, use 0–1 V to set the minimum level, and use 1–10 V
for continuous dimming.
Note:
4-11/16 in back boxes, or on back boxes with round cover plates.
The canopy fixture cannot be installed on 1-gang back boxes or
trim rings.
WARNING:
as directed below for installations where the interior of the
canopy enclosure could be exposed after installation with only
the mounting plate. For example, install the cover plate when
installing to a surface-mount back box.
AVERTISSEMENT :
indiqué ci-dessous pour les installations où l'intérieur de la
rosace de plafond pourrait être exposé après l'installation
avec uniquement la plaque de montage. Par exemple, installez
la plaque de protection lors de l'installation sur un boîtier
arrière à montage en surface.
1.
Remove the adhesive tape or
fasteners securing the
mounting plate to the fixture
to free the mounting plate
from the canopy enclosure.
Irideon WLZ User Manual
The 0–10 V driver conforms to IEC 60929 Annex E. Of the
The canopy fixture can be installed directly on 4 in and
RISK OF ELECTRIC SHOCK! Install the cover plate
Installez la plaque de protection comme
Cover plate
(if needed
for surface-
mounting)
Mounting
plate
Mounting
plate bolts
Canopy
bolts
11