6. Connect the data wires to the fixture wiring using the included
WAGO connectors.
For 0–10 V fixtures: Connect the gray wire to data - and the
purple wire to data +.
For DALI fixtures: Connect the purple wires to data - and
data +.
7.
Use the canopy bolts to secure the
fixture to the mounting plate.
8. Insert the oval-shaped covers into the
canopy enclosure to cover the canopy
bolt openings.
Oval-shaped covers
9. Restore power at the disconnect device.

Install Portable Fixture with C-clamp

The C-clamp attaches the fixture to the mounting pipe and allows you to
adjust the position of the fixture once it is mounted. The C-clamp will fit
a 3/4 in to 2 in pipe. Two different length pipe bolts are provided to
accommodate different pipe sizes.
Note:
only in non-EU markets. Within the EU, use an M12 bolt to secure
a clamp (provided separately) to the fixture.
Irideon WLZ User Manual
The miniature C-clamp for the portable fixture is available
Canopy
bolts