If using Belden 9729:
a. See the DMX Cable
b. Install the screw terminal
If using Category 5:
a. See the Cat5 Cable Preparation
b. Install the IDC connector with
4. Optionally, terminate DMX/RDM thru to the next device in the DMX
data run. Up to 32 DMX/RDM devices can be daisy-chained
together per data run.
a. See the specific termination setup guide for the type of cable
b. Install the connector with wires terminated to the DMX/RDM
Irideon WLZ User Manual
Preparation for Screw
Termination Setup Guide for
instructions to prepare and
terminate Belden 9729 for
DMX input cable to the screw
terminal connector.
connector with wires
terminated to the DMX/RDM
Input receptacle on the
termination board.
for IDC Termination Setup
Guide for instructions to
prepare and terminate
Category 5 for DMX/RDM input
cable to the insulation
displacement connector.
wires terminated to the
DMX/RDM Input receptacle on
the termination board.
used (either Belden 9729 or Category 5) in the installation.
Termination kits are ordered separately.
Thru receptacle on the termination board.
From a DMX/RDM source
4 to 8 = n/c
Belden 9729 (or equivalent) wire
termination to screw connector
Cat5 (or equivalent) wire
termination to IDC connector