ETC Irideon WLZ User Manual page 13

Hide thumbs Also See for Irideon WLZ:
Table of Contents

Advertisement

1
2
4. Connect the pre-wired DMX connector on the fixture to the mated
connector on the mounting plate (shown below).
5. Terminate DMX/RDM data signal for the last DMX/RDM device in
the data run by setting the termination switch to ON (to the right,
as shown below). All other devices in the data run should retain
the default setting for the termination switch (OFF).
6. Following the label on the mounting plate, attach the power wires
to the power block.
Irideon WLZ User Manual
Mounting plate
(DMX variant)
Canopy
bolt hole
2.
Hook
3. If desired, manually set the DMX address
2
For this
structure...
4-11/16 in
back box
4 in back box
1
Use the hook in the canopy enclosure to
hang the fixture from the mounting plate
while you complete the fixture wiring.
on the fixture using the three addressing
dials in the canopy. See
Address at the Fixture on page 16
...secure mounting
plate using:
Large oval slots
(see 1 at left)
Small oval slots
(see 2 at left)
Set the DMX
Mounting plate
DMX connector
Termination switch
Power block
.
9