Install Canopy Fixture (DMX variant)

Note: The canopy fixture can be installed directly on 4" and
Install the Voltage Barrier (DMX variant)
The DMX variant of the canopy fixture includes a voltage barrier to separate
the data network from the line voltage inside the backbox. Voltage barriers are
provided for both 4" and 4-11/16" backboxes.
CAUTION: • DMX control is a Class 2 circuit. DMX wiring cannot be
Install the voltage barrier in the backbox with
the provided screw, separating the power
side from the data side (see image at right).
User Manual
4-11/16" backboxes, or on backboxes with round cover
plates. The canopy fixture cannot be installed on 1-gang
backboxes or trim rings.
run through the same conduit as line voltage power-
supply conductors.
• Separate the line voltage from the data side in the
backbox. Install the voltage barrier provided by ETC.