6.2
Life Expectancy of Major Parts
Parts
Antenna motor
D8G-516 (24 rpm, X-band)
D8G-571 (42 rpm, X-band)
GOB-8222 (18/22 rpm, X-band, 200 VAC)
RM-6585 (18/22 rpm, X-band, 24 VDC)
RM-7398 (21/26 rpm, S-band)
RM-7435 (21/26 rpm, S-band)
RM-9519 (45 rpm, S-band)
RM-9520 (45 rpm, S-band)
RM-9521 (45 rpm, S-band)
Magnetron
9M31(F) (X-band, 50 kW)
MAF-1425B (X-band, 12 kW)
MG4010 (X-band, 12 kW)
MG5240 F (S-band, 60 kW)
MG5436 (X-band, 25 kW)
MG5223F (S-band, 30 kW)
Backlight Unit for
201LHS2F
Display Unit
MU-201CR
Cold Cathode
FLCL-23
Fluorescent Lamp
for Display Unit
MU-231CR
6.3
Replacing the Fuse
The fuse at the rear of the processor unit
in the display unit protects the equipment
from overcurrent (overvoltage in case of
AC set) and equipment fault. If you cannot
turn on the power, first check the fuse.
Find the cause of the trouble before
replacing the fuse. Be sure to use the
proper fuse. Use of a wrong fuse can
seriously damage the equipment and void
the warranty.
Unit
Processor Unit
Power Supply Unit PSU-006
Display Unit MU-201CR
Display Unit MU-231CR
Type
Ship's mains and fuse to use
Power
24 VDC
100-115 VAC
220-230 VAC
100-115 VAC
220-230 VAC
100-230 VAC
24 VDC
100-230 VAC
24 VDC
6. MAINTENANCE, TROUBLESHOOTING
Life expectancy Remarks
Gears more than
10,000 h
2,000 - 3,000 h
45,000 h(25°C)
30,000 h(50°C)
50,000 h(25°C)
35,000 h(50°C)
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment or cause fire.
Fuse to use
20A
10A
5A
5A
3A
2A
5A
2A
6A
Wind load
100 kt
6-3