1. RADAR OPERATION
1.43.2

Outputting alarm signal

Four ports are provided from which to output alarm signals to external equipment.
Choose the port and alarm signals to output as follows:
1. Roll the trackball to choose the MENU box and then push the left button.
2. Roll the wheel to choose 3 ALARM and then push the wheel or the left
button.
3. Roll the wheel to choose appropriate "ALARM OUT" item (6-9), and then
push the wheel or the left button.
1-82
[ALARM]
1 BACK
2 GUARD ALARM MODE
IN/OUT
3 GUARD ALARM LEVEL
1/2/3/4
4 WATCH ALARM
OFF/6M/10M/
12M/15/20M
5 ALARM SOUND LEVEL
LOW/MID/HIGH
6 [ALARM OUT1]
7 [ALARM OUT2]
8 [ALARM OUT3]
9 [ALARM OUT4]
0 AUDIO ALARM
OFF/ON
ALARM menu
[ALARM OUT1]
1 BACK
2
TARGET ALARM
WATCH ALARM
GUARD ZONE
LOST TARGET
CPA LIMIT
AUTO ACQ TGT FULL
MAN ACQ TGT FULL
ARP SYSTEM ERROR
AZIMUTH
HEAD LINE
TRIGGER
VIDEO
GYRO
LOG
EPFS
XTE
ARRIVAL WPT
DEPTH
ALARM ACK OUT
OPERATOR FITNESS
9 ALARM OUT POLARITY
NORMAL/INVERT