Chapter 30 Event History Function; Event Information To Be Registered - Mitsubishi Electric MELSEC iQ-R Series User Manual

Programmable controller
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

30
EVENT HISTORY FUNCTION
This function collects and saves the following information: errors detected by this product, operations performed for this
product, and errors occurred on a network.
Saved information about errors and operations can be checked in chronological order using Windows Event Viewer and CW
Configurator.
Precautions
The save destination for an event history file cannot be changed. The storage capacity for the event history is 128 KB.
30.1

Event Information to be Registered

This section shows the event information that are registered by using the event history function and its registration destination.
Event
Service and driver event information
Bus control event information
*1 An error may occur between the actual occurrence date and the date logged in the Windows event log.
Service and driver event information
This information refers to errors and events that are detected by services and drivers of this product running on Windows.
Registered event information can be checked in Windows Event Viewer. (Page 223 Checking Events with the Event
Viewer)
[Event Viewer]  [Applications and Services Logs]  [MELSEC Service]
Bus control event information
This information refers to errors and events for the bus control that are detected by this product or other modules controlled by
this product.
Registered event information can be checked in the event history screen of CW Configurator. (Page 224 Checking Errors
in CW Configurator)
If this information is registered in the Windows event log, it can be checked by selecting the following menu in Windows Event
Viewer.
[Event Viewer]  [Applications and Services Logs]  [MELSEC Bus Event]
Precautions
• A bus control event is registered in Windows Event Viewer after Event Log Service is started. Note that the event is not
registered when turning the power of this product OFF and ON or when Event Log Service is not running. To check a bus
control event while Event Log Service is not running, check the event in the event history screen of CW Configurator.
• Due to processing for registering an event to Windows Event Viewer, the date and time displayed in the "Logged" of an
event log, which is registered in Windows Event Viewer, may be different from the occurrence date and time of an event
displayed in the bus control event history. To check whether the same event is registered, compare the following items:
'An event code in the bus control event history'
'An event code in the dialog box of an event registered in Windows Event Viewer'
• When changing a time zone on Windows, the time in the "Logged" of event logs, which are registered in Windows Event
Viewer, is corrected according to the changed time zone. Therefore, the date and time of the event logs may be different
from that of events in the event history because time in the event history is not corrected by the changed time zone.
Registration destination
Windows event log
Registered.
Only specified events are registered.
(Page 216 Registration Destination for Event
Information)
Bus control event history
• Error: Registered.
• Event: Not registered.
*1
Registered.
30 EVENT HISTORY FUNCTION
30.1 Event Information to be Registered
30
215

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r melsecwincpu

Table of Contents