Chapter 3 Function List - Mitsubishi Electric MELSEC iQ-R Series User Manual

Programmable controller
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

3
FUNCTION LIST
This chapter shows the function list of this product.
Function
Windows function
MELSEC functions
Module operation
functions
Diagnostics and
maintenance functions
3 FUNCTION LIST
30
Programmable controller device memory
function
Bus access function
MELSOFT connection function
Time synchronization function
Multiple CPU system function
Network module access function
Label communication function
Fixed cycle processing function
Remote operation function
Hardware reset function
Individual reset function
Windows shutdown function
Windows forced restart at error function
Y output control function
INFORMATION LED operation function
Bus access diagnostics function
Watchdog timer function
self-diagnostics function
Error clear function
Event history function
Parameter/event history initialization
function
Description
To use Windows functions with Windows 10 IoT Enterprise LTSC 2019 installed on
this product
To enable access to devices and buffer memory of this product from Windows
applications in this product and external devices via a bus and Ethernet
To link with another module using the bus driver of this product
To connect MELSOFT products (up to 16 products) on a network using the Ethernet
port of this product
To synchronize time between this product (Windows) and the CPU module (CPU
No.1) when configuring a multiple CPU system
To allow each CPU module on a base unit to control an I/O module and an intelligent
function module
To communicate data with devices on a network via a network module controlled by
this product
To read/write data from/to labels stored in a CPU module on another station
To refresh with a network module and perform data communication with an external
device
To change the operating status of this product by changing the Y output status and
resetting a bus with peripheral devices and user programs
To reset hardware
To reset (restart) Windows and the bus control in this product individually
To shut down Windows in this product by using a switch or input of an I/O module
To restart Windows in this product automatically when the Windows freezes or a
system error occurs in the Windows
To control the Y output status (Y STOP/Y OUT/PAUSE) with the BUS RESET/Y
STOP/Y OUT switch or a MELSEC data link function
To operate the display status of the INFORMATION LED from a user program
To diagnose whether there are failures in hardware used for the bus access function
of this product
To monitor and detect a bus control failure with the watchdog timer (WDT), which is
an internal timer of this product, and to notify an error if the failure occurs
To diagnose whether there are any errors in this product
To clear all the continuation errors in this product
To collect and save the following information: errors detected by this product,
operations performed for this product, and errors occurred on a network
To return this product to the factory default state by initializing the parameters and
bus control event history of this product