System information
The special relays for system information are as follows.
No.
Name
SM217
Daylight saving time status
flag
*1*2
SM220
CPU No.1 preparation
completed
*1*2
SM221
CPU No.2 preparation
completed
*1*2
SM222
CPU No.3 preparation
completed
*1*2
SM223
CPU No.4 preparation
completed
SM230
CPU No.1 error flag
SM231
CPU No.2 error flag
SM232
CPU No.3 error flag
SM233
CPU No.4 error flag
*2
SM240
CPU No.1 reset flag
*2
SM241
CPU No.2 reset flag
*2
SM242
CPU No.3 reset flag
APPX
274
Appendix 4 Special Relay List
Description
Details
OFF: Not during daylight
This relay turns ON when the time setting is in the
saving time
daylight saving time by using daylight saving time
ON: During daylight
function.
saving time
This relay turns OFF when the time setting is not in the
daylight saving time.
OFF: CPU No.1
This relay turns ON when the access from another CPU
preparation not
module to the CPU No.1 is enabled after turning the
completed
power ON or resetting the module.
ON: CPU No.1
preparation completed
OFF: CPU No.2
This relay turns ON when the access from another CPU
preparation not
module to the CPU No.2 is enabled after turning the
completed
power ON or resetting the module.
ON: CPU No.2
preparation completed
OFF: CPU No.3
This relay turns ON when the access from another CPU
preparation not
module to the CPU No.3 is enabled after turning the
completed
power ON or resetting the module.
ON: CPU No.3
preparation completed
OFF: CPU No.4
This relay turns ON when the access from another CPU
preparation not
module to the CPU No.4 is enabled after turning the
completed
power ON or resetting the module.
ON: CPU No.4
preparation completed
OFF: CPU No.1 normal
• This relay turns OFF when the CPU No.1 is normal
ON: CPU No.1 stop error
(including a continuation error status).
state
• This relay turns ON when the CPU No.1 is in stop error
state.
OFF: CPU No.2 normal
• This relay turns OFF when the CPU No.2 is normal
ON: CPU No.2 stop error
(including a continuation error status).
state
• This relay turns ON when the CPU No.2 is in stop error
state.
OFF: CPU No.3 normal
• This relay turns OFF when the CPU No.3 is normal
ON: CPU No.3 stop error
(including a continuation error status).
state
• This relay turns ON when the CPU No.3 is in stop error
state.
OFF: CPU No.4 normal
• This relay turns OFF when the CPU No.4 is normal
ON: CPU No.4 stop error
(including a continuation error status).
state
• This relay turns ON when the CPU No.4 is in stop error
state.
OFF: CPU No.1 not being
• This relay turns OFF when the CPU No.1 is not being
reset
reset.
ON: CPU No.1 being
• This relay turns ON while the CPU No.1 is being reset
reset
(including the case when the CPU module is removed
from the base unit). Other CPUs also will be in the reset
state.
OFF: CPU No.2 not being
• This relay turns OFF when the CPU No.2 is not being
reset
reset.
ON: CPU No.2 being
• This relay turns ON while the CPU No.2 is being reset
reset
(including the case when the CPU module is removed
from the base unit). Errors occur in the other CPU
modules.
OFF: CPU No.3 not being
• This relay turns OFF when the CPU No.3 is not being
reset
reset.
ON: CPU No.3 being
• This relay turns ON while the CPU No.3 is being reset
reset
(including the case when the CPU module is removed
from the base unit). Errors occur in the other CPU
modules.
Set by (when to set)
S (status change)
S (status change)
*3
S (status change)
*3
S (status change)
*3
S (status change)
*3
S (status change)
S (status change)
S (status change)
S (status change)
S (status change)
S (status change)
S (status change)