Chapter 2 Safety regulations

Protection devices

Operate the system only if all safety- and protection devices are completely available and
functional. Check the protection devices for its function:
At first operation.
At regular routine test.
After exchange of security-relevant components and parts
If deficiencies occur during operation at the protection devices, stop the system
immediately and remedy the deficiencies! Do not change or remove any protection
devices. Do not take the protection devices out of operation by any change.
Protection devices may only be removed for maintenance- and repair purposes and when
the system is stopped and safeguarded against re-starting of the system (e.g. padlock at
main switch). If subcomponents are supplied, the protection devices have to be installed
according to the regulations by the operator.
Connection to the customer's conveying system may evoke dangerous areas at the
transitions. Suitable safety measures have to be taken in this case.
*² Labeling station's cover
The fixed and screwed system covers protect the user against mechanical hazards.
*² Main switch
Fig. 2-2: Main switch
Lock always the main switch:
During maintenance- and service works.
If switching on the system may lead to a hazard
*² Emergency-Stop Push Button
Fig. 2-3: Emergency-Stop
Push Button
Version: 12.05.14
The main switch serves for switching the system on and off and
emergency stop. In position "0" it interrupts the power supply to
the system but however the supply in front of the switch can be
energized.
The main switch can be locked in position "0" as a protection
against a hazard by accidentally or unauthorized switching on
the system.
The emergency stop pushbutton serves for an immediate
stopping of the complete labeling system. It should only be used
in emergency situations. The emergency stop push button is
locked after actuation and has to be locked manually before
restarting (consider the information at the button).