Chapter 11. Updating Firmware
TFTP FIRMWARE UPDATES
Updating Firmware using TFTP
11-4
PLUS
ATLAS 800
supports firmware updates to any module via the 10BaseT
Ethernet port using TFTP from a network server. The network server must
be capable of supporting TFTP server requests from the TFTP client within
PLUS
ATLAS 800
.
Before beginning this procedure,
•
you must have a level 2 password to perform updates of any modules
within ATLAS. Please consult the ATLAS administrator if this pass-
word is not known.
•
you must obtain the appropriate update file for the particular module
from ADTRAN Technical Support at (888) 4ADTRAN (423-8726).
•
you must copy the update file provided by ADTRAN to a network serv-
er that supports TFTP server requests. Record both the IP address of the
server and the full path location of the update file to be downloaded.
Instructions for Updating Firmware Using TFTP
Step
1
Using a Telnet program,
2
Select System Utility / Update Firmware (see Figure 11-2).
Move the cursor to Module Slot , and press
appropriate module slot to update.
To update multiple modules of the same type, select All
3
Modules of a Type from Module Slot . (Only upgradable
modules are displayed as choices for Module Type when
updating All Modules of a Type in the ATLAS.)
4
Select TFTP for the Transfer Method .
Enter into TFTP Server IP Address , the IP address of the
5
network server that was recorded earlier.
Enter into TFTP Server Filename , the full path name and
6
filename of the update file that was recorded earlier.
From Restart Schedule , select the time for the module to perform
7
a restart after completing the update process (see Restart
Schedule on page 6-14).
PLUS
ATLAS 800
Action
to ATLAS.
log in
User Manual
Enter
. Select the
61200226L1-1