Chapter 12. SNMP Management
Total Alert
adATLAS800TotalLES
adATLAS800TotalLCV
12-6
Severity
Warning The total interval line errored second threshold has been
exceeded.
Warning The total interval line code violation threshold has been
exceeded.
When one of the Total Alert thresholds is exceeded, the corresponding event
bit is set to 1 in the adDS1TotalAlert variable in the DS1 alert table. When en-
PLUS
abled, ATLAS 800
sends alert traps to each member of the trap destina-
tion list upon detecting status bit changes in adDS1TotalAlert. If you have
previously set the corresponding enable bit = 1 in the adDS1TotalArm vari-
able and adDS1AlertEnable = On, then ATLAS 800
message. A single alert trap message may report multiple event changes.
PLUS
ATLAS 800
clears the event bits after sending the trap message or send-
ing the response to a Get request for the adDS1TotalAlert variable.
Current Alert and Total Alert described above are Near End events.
PLUS
ATLAS 800
also supports Current Alert and Total Alert for the Far End.
Far End alert traps are generated upon status bit changes in
adDS1FarCurrentAlert for Current Alerts and adDS1FarTotalAlert for Total
Alerts. Current and Total Far End Alerts can be disabled by setting the cor-
responding enable bit = 0 in the adDS1FarCurrentArm and
adDS1FarTotalArm variables, respectively. Far End alert traps can also be
disabled by setting adDS1AlertEnable = Off.
PLUS
ATLAS 800
Table 12-5. Total Alert Traps
Description
PLUS
User Manual
sends an alarm trap
61200226L1-1