Chain Port Tx Bytes; Chain Port Rx Bytes; Chain Port Overrun Errs; Chain Port Framing Errs - ADTRAN ATLAS 800 PLUS User Manual

Hide thumbs Also See for ATLAS 800 PLUS:
  • Q&a (22 pages)
Table of Contents

Advertisement

» Chain Port Tx
Bytes
» Chain Port Rx
Bytes
» Chain Port
Overrun Errs
» Chain Port
Framing Errs
» Clear Chain Port
Countrs
SYSTEM
>
CONFIG
» Primary Timing
Source
» Backup Timing
Source
» ADLP Address
61200226L1-1
Read security: 5
Displays the number of transmitted data bytes.
Read security: 5
Displays the number of received data bytes.
Read security: 5
Displays the number of overrun errors.
Read security: 5
Displays the number of received framing errors.
Clears all chain port counters. Press Y to activate command.
The System Config menu allows you to set up the ATLAS operational con-
figuration. Figure 6-3 shows the items included in this menu.
Write security: 3; Read security: 5
Selects the primary timing source. You can select either
from one of the installed modules.
Write security: 3; Read security: 5
Selects the secondary timing source. You can select either
port from one of the installed modules. ATLAS 800
timing source if the primary timing source goes into alarm. The Backup
Timing Source should be different from the Primary Timing Source .
Write security: 2; Read security: 5
Shows the system ADTRAN Data Link Layer Protocol (ADLP) address for
connecting remote devices to management software (such as T-Watch PRO).
The allowable range is between 2 and 65520. Enter a value not used by any
of the TSU units controlled by the management software.
PLUS
ATLAS 800
Chapter 6. Terminal Menu and System Control

Figure 6-3. System Configuration Menu

User Manual
or a port
INTERNAL
or a
INTERNAL
PLUS
uses the backup
6-7