Assembly "Internal mounting kit, type 05-0091-0275"

Rev. 0
Mounting the atmosphere measuring point when mounting the Ex p control unit
inside the protected equipment
Procedure:
 Make a 16.5mm diameter bore hole at the intended location on the
pressurized enclosure.
 Screw the bleed screw (1) together with the sleeve (2) in the bore hole.
 Screw the reduction (3) into the sleeve (2).
 Screw the hose connection (4) into the reduction (3).
 Push in the hose (5) into the hose connection (4) and lead it to the
internally installed Ex p control unit.
 Replace the atmospheric measuring point by hose connection (4) and
insert hose.
Schematic diagram: