Download Print this page
Bartec 17-A1Z0-0005 Installation Instruction

Bartec 17-A1Z0-0005 Installation Instruction

Hart add-on module
Hide thumbs Also See for 17-A1Z0-0005:

Advertisement

Quick Links

Installation Instruction
HART Add-On Module

Advertisement

loading

Summary of Contents for Bartec 17-A1Z0-0005

  • Page 1 Installation Instruction HART Add-On Module...
  • Page 2 Installation Instruction - Translation HART Add-On Module Typs 17-A1Z0-0005, B7-A2Z0-0033 and G7-A0Z0-0007 Version for: Non hazardous areas  ATEX/IECEx Zone 1 and Zone 2  UL Class I Division 1 and Division 2  Document No.: B1-A2Z0-7N0001 / 400570 Revision A - Status: 29. September 2016 Reservation: Technical data subject to change without notice.
  • Page 3 Injuries and material damage can be avoided by circumspect handling and systematically following the instructions. The BARTEC company reserves the right to carry out technical changes at any time. Maintenance and Repairs The pertinent erection and operating provisions for electrical systems must be observed! Repairs to explosion-protected devices may only be performed by authorised personnel with original spare parts and according to the state of the art.
  • Page 4 The use in areas other than those specified or alteration of the product releases BARTEC from liability for defects and further liability. Modifications and changes to the module are not permitted. The generally applicable statutory regulations and other binding guidelines on occupational health and safety, on accident prevention and on environmental protection must be complied with.
  • Page 5 Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007 Marking, test certificate, and standards Note: Full information see "user manual" tablet PC. Type 17-A1Z0-0005 for tablet PC "Agile X IS" ATEX Zone 1 EPS 15 ATEX 1 069 X II 2G Ex ia [ia Ga] IIC T4 Gb...
  • Page 6 The apparatus shall be protected against mechanical impact, excessive UV-light and strong charge generating processes. In combination with Bartec accessory 03-9849-0130 (hand strap) the device is only suited for gas group IIA. It is allowed to connect the HART add on module to non certified HART circuits outside hazardous areas.
  • Page 7 Installation Instruction HART Add-On Module (Translation) Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007 Device / system specification HART interface ≤ DC 30 V ≤ 130 mA ≤ 1 W ≤ DC 3 V ≤ 10 mA ≤ 5 mW ≤ DC 60 V max.
  • Page 8 Installation Instruction HART Add-On Module (Translation) Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007 Introduction The intrinsically safe combination of the tablet PC system and the newly developed HART Add-On Module makes it possible to perform diagnostics, set parameters and manage field devices much more quickly and efficiently.
  • Page 9 Installation Instruction HART Add-On Module (Translation) Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007 Installation HART Add-On Module Only assemble/dismantle the HART Add-On Module outside the potentially explosive atmosphere. Only use the HART Add-On Module for the purpose that they have been tested and certificated by BARTEC..
  • Page 10 Installation Instruction HART Add-On Module (Translation) Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007 Fasten the HART Add-On Module using the six screws supplied. Torque 3 Nm. Visual inspection of the HART Add-On Modules to ensure correct positioning and assembly. Switch the tablet PC on using the "ON/OFF"...
  • Page 11 Installation Instruction HART Add-On Module (Translation) Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007 Setting up/activating the HART Add-On Module Switching the tablet PC on. Press the ON/OFF button for three  seconds. Activating the HART Add-On Module. (1) Click on "Hottab" on the start screen to start the application.
  • Page 12 Installation Instruction HART Add-On Module (Translation) Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007 Downloading and installing driver software If the driver for the virtual COM port is not listed in the tablet PC’s system image, a new "CP2109 USB to UART Bridge Controller" device will appear under "Other devices"...
  • Page 13 Installation Instruction HART Add-On Module (Translation) Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007 The "User Account Control" (UAC) window opens. Start installation by clicking on "Yes". Continue installation in the "CP210x USB to UART Bridge Driver Installer" window clicking on "Next".
  • Page 14 Installation Instruction HART Add-On Module (Translation) Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007 Drivers were "The successfully installed on this computer" message appears in the window. Complete installation by clicking on "Finish". 10. Once the driver has been installed, the HART Add-On Module can be found in the device manager under: "Ports (COM &...
  • Page 16 Your partner for safety technology. Challenge us! BARTEC GmbH Max-Eyth-Str. 16 Phone: +49 7931 597 0 info@bartec.de Germany 97980 Bad Mergentheim Fax: +49 7931 597 119 www.bartec.de...

This manual is also suitable for:

B7-a2z0-0033G7-a0z0-0007