Bartec POLARIS SMART HMI 17-71V6-1 Series User Manual

7” w
Table of Contents

Advertisement

User Manual - TRANSLATION
POLARIS SMART HMI
POLARIS SMART HMI 7" W
Typ 17-71V6-1....
ATEX / IECEx
Zone 1 and Zone 21
Document no. 11-71V6-7D0001 / 411983
Revision 1 / Status: 04 April 2018
Reservation: Technical data subject to change without notice. Changes, errors and
misprints may not be used as a basis for any claim for damages.
GmbH
Max-Eyth-Straße 16
97980 Bad Mergentheim
GERMANY
Content
English
Phone: +49 7931 597-0
Fax: +49 7931 597-119
Pages
1 - 54
Support:
support-polaris@bartec.de
Download:
http://automation.bartec.de
Internet:
www.bartec.de

Advertisement

Table of Contents
loading

Summary of Contents for Bartec POLARIS SMART HMI 17-71V6-1 Series

  • Page 1 Content Pages English 1 - 54 GmbH Max-Eyth-Straße 16 Phone: +49 7931 597-0 Support: support-polaris@bartec.de 97980 Bad Mergentheim Fax: +49 7931 597-119 Download: http://automation.bartec.de GERMANY Internet: www.bartec.de...
  • Page 3 POLARIS SMART HMI - for Zone 1/21 Table of Contents POLARIS Smart HMI 7” W Technical data subject to change. 04/2018...
  • Page 4: Table Of Contents

    POLARIS SMART HMI - for Zone 1/21 Table of Contents POLARIS Smart HMI 7” W Basic safety instructions ........................1 Notes on this manual ........................ 1 1.1.1 Languages ........................2 1.1.2 Changes to the document .................... 2 Handling the product ......................... 2 Use in accordance with the intended purpose ................
  • Page 5 Embedded MUI ....................36 8.5.1 EWF (Enhanced Write Filter) ..................36 Onboard Bartec Recovery Solution..................38 8.6.1 Bartec Recovery Solution ................... 38 8.6.2 Start of the device in the Recovery mode ..............39 8.6.3 Recovery surroundings ....................39 8.6.4 4. Recovery application ....................40 8.6.5 Restoration in the work state ..................
  • Page 6 POLARIS SMART HMI - for Zone 1/21 Table of Contents POLARIS Smart HMI 7” W Technical data subject to change. 04/2018...
  • Page 7: Basic Safety Instructions

    They are not necessarily true to scale and may deviate slightly from the actual construction of the device. The BARTEC company reserves the right to carry out technical changes at any time. In no event will BARTEC company be responsible or liable for indirect or consequential damages resulting from the use or application of this user manual.
  • Page 8: Languages

    1.1.2 Changes to the document BARTEC reserves the right to alter the contents of this document without notice. No guarantee is given for the correctness of the information. In case of doubt, the German safety instructions shall apply because it is not possible to rule out errors in translation or in printing.
  • Page 9: Improper Use

    POLARIS SMART HMI - for Zone 1/21 Basic POLARIS Smart HMI 7” W safety instructions 1.3.2 Improper use Any other use is not in accordance with the intended purpose and can cause damage and accidents. The manufacturer will not be liable for any use beyond that of its Exclusive II intended purpose.
  • Page 10: Maintenance

    Basic POLARIS SMART HMI- for Zone 1/21 safety instructions POLARIS Smart HMI 7” W 1.6.2 Maintenance Regular servicing is not necessary if the equipment is operated correctly in accordance with the installation instructions and environmental conditions. In this context, please refer to Chapter "Maintenance, Inspection, Repair".
  • Page 11 We guarantee the POLARIS and its accessories for a period of 1 year starting from the BARTEC delivery date. This guarantee covers all parts of the delivery and is restricted to the replacement free of charge or the repair of the defective parts in our Bad Mergentheim factory.
  • Page 12: Product Description

    The intrinsically safe USB interfaces can be reached directly on the back. Wired electrical connections are made via integrated terminal compartments. The use of the BARTEC Ex i memory stick through the intrinsically safe USB interface allows data to be transferred easily, stored, and saved for system restoration by means of the backup function The front-panel mounting design makes installation easy.
  • Page 13: Schematic Design

    POLARIS SMART HMI - for Zone 1/21 Product description POLARIS Smart HMI 7” W Schematic design Illustration 2: System configuration Technical data subject to change. EN 7/54 04/2018...
  • Page 14: Explosion Protection And Approvals

    Explosion protection and POLARIS SMART HMI - for Zone 1/21 approvals POLARIS Smart HMI 7” W Explosion protection and approvals POLARIS SMART HMI Type 17-71V6-1…. ATEX Ex protection type II 2G Ex eb q [ib] IIC Gb bzw. II 2D Ex tb IIIC T120° Db -20 °C ≤...
  • Page 15 POLARIS SMART HMI - for Zone 1/21 Explosion protection and POLARIS Smart HMI 7” W approvals Further test certificates More test certificates www.bartec.de EU-conformity RoHS-Directive 2011/65/EU Standards in accordance with EN/IEC 61000-6-2:2005 EMC Directive 2014/30/EU EN 61000-6-4:2007 + A1:2011 IEC 61000-6-4:2006 + A1:2010...
  • Page 16: Technical Data

    POLARIS SMART HMI for Zone 1/21 Technical data POLARIS Smart HMI 7” W Technical data POLARIS SMART HMI 7” Construction Front panel fitting Computer capacity CPU Intel ® Atom (E 3826), Dual Core with 2 x 1,46 GHz, RAM: 2 GB, 4 GB internal flash drive Optional: CPU Intel ®...
  • Page 17 POLARIS SMART HMI - for Zone 1/21 Technical data POLARIS Smart HMI 7” W Power supply DC 24 V ±10 % Max. power consumption (inkl. USB) < 25 W max. (without USB) < 20 W max. Normal use without USB approx. 12,5 W Relative air humidity 5 to 95 % non-condensing 0.7 G/1 mm;...
  • Page 18: 4.2 Keyboard

    -20 °C ≤ Ta ≤ +60 °C Certification IBExU 05 ATEX 1117 X Ex protection type IECEx Ex ib IIC T4 Ex ib IIIC T120 °C Certification IECEx IBE 11.0007X www.bartec.de More test certificates 4.2.3 General Data Construction Front panel fitting Material Stainless steel...
  • Page 19: Ex I Memory Stick

    Certification DEMKO 16 ATEX 1803 Rev. 0 Ex protection type IECEx Ex ib IIC T4 Certification IECEx UL 16.0160 www.bartec.de More test certificates Type 17-71VZ-5100/02** Ex protection type ATEX II 2G Ex ib IIC T4 Gb -20 °C ≤ Ta ≤ 60 °C...
  • Page 20: Usb Smart Device

    POLARIS SMART HMI for Zone 1/21 Technical data POLARIS Smart HMI 7” W USB Smart Device 4.4.1 Explosionsschutz Type 17-71VZ-A0x0/0000 Ex protection type ATEX II 2G Ex eb mb IIC T4 Gb II 2D Ex tb IIIC T120 °C Db Certification IBExU 05 ATEX 1117 X Ex eb mb IIC T4...
  • Page 21: Electric Data (Usb Standard)

    POLARIS SMART HMI - for Zone 1/21 Technical data POLARIS Smart HMI 7” W 4.4.3 Electric data (USB standard) USB-connection Colour Function Data- USB-data signal Data+ USB-data signal Bluetooth 4.4.4 Technical data (Bluetooth) Bluetooth Downward compatible 2.0 / 2.1 / 3.0 Up to 10m (free terrain) Range For more technical data see description of the bluetooth-stick manufacturer.
  • Page 22: Product Labelling

    POLARIS SMART HMI for Zone 1/21 Technical data POLARIS Smart HMI 7” W Product Labelling Type label depending on the operating system Licence sticker Warnings on the device Warnhinweis auf Klemenraum! Technical data subject to change. EN 16/54 04/2018...
  • Page 23: Transport, Storage, Scope And Assembly

    A written report of any transport damage or missing items must be given to the appointed forwarder and to BARTEC GmbH immediately on receipt of the delivery. Damage caused by incorrect storage and transport shall not fall within the warranty provisions of BARTEC GmbH.
  • Page 24: Assembly

    Transport, Storage, POLARIS SMART HMI- for Zone 1/21 Scope and Assembly POLARIS Smart HMI 7” W Assembly Before assembling the device, make sure you have all the components and documents. POLARIS - mounting clamps Required 1 x hex key 3 mm Tools: 1 x socket wrenches 7 mm POLARIS –...
  • Page 25: Installation

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W Installation We recommend setting up and testing the entire system before its ultimate installation in the ex-area. If a long connection cable is not available, please use a patch cable to test the basic functions.
  • Page 26: Mechanical Installation

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W Choose the optimum height for operating the POLARIS. Ensure good lighting conditions for a perfectly legible display (no direct exposure to the sun’s rays). Do not mount in direct proximity to switching or current changing devices. Only install the POLARIS in conjunction with the reinforcement frame in an IP65 enclosure.
  • Page 27: Installation I 2G-/3G-Enclosure

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W Illustration 4: Rear panel 6.2.1 Installation i 2G-/3G-enclosure In order to guarantee the IP degree of enclosure protection = IP54 for installation in 2G enclosures of Ex e type of protection (e.g. control equipment), and = IP6X for installation in 2D enclosures in areas where combustible dusts exist - with “protection through the enclosure”...
  • Page 28: Mechanical Fitting

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W 6.2.2 Mechanical fitting Work steps (1) Insert the POLARIS into the cut-out in the enclosure. (2) From the back, place the reinforcement frame over the POLARIS. (3) Using the M4x12 (2) screws to fasten the mounting clamps (1) to the rear side of the POLARIS and tighten to 1.3 Nm.
  • Page 29: Electrical Installation

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W Electrical Installation 6.3.1 Installation guidelines Only qualified personnel, i.e. trained electricians will have the required specialised knowledge to be able to do all the electrical work. Familiarity with and the technically perfect implementation of the safety instructions described in this manual are preconditions for safe installation and commissioning.
  • Page 30: Rear Panel Overview

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W Rear panel overview Ex i-USB 1 Ex i-USB 2 Reinforcement frame Retaining claws Sealed locking Terminal compartment screw Ex-e Do not open! PE-Connection Cable glands Illustration 5: Rear panel overview DANGER Sealed locking screw! The device is closed in the factory.
  • Page 31: Pe Conductor Connection

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W PE conductor connection DANGER Death or danger of injury as a result of no PE conductor connection. There is no explosion protection. Equipotential bonding with a core cross-section of at least 4 mm is to be set up for the POLARIS (see Figure).
  • Page 32: Ex E Terminal Compartments

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W Ex e terminal compartments 6.6.1 Cable entries When connecting cables and leads to supplies / communications equipment in increased safety protected areas, Ex certified cable entries must be used which are suitable for each type of cable and lead.
  • Page 33: Supply Voltage Terminal Assignment)

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W 6.6.2 Supply voltage terminal assignment) Mains Connection Variant DC 24 V Terminal Interface Signal Remarks Supply DC 24 V ± 10 % Supply 0 Volt Supply Protective earth 6.6.3 Ethernet Terminal Assigment Configuration Ethernet...
  • Page 34: Interface 2X Usb (Max.480 Ma)

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W 6.6.4 Interface 2x USB (max.480 mA) Configuration USB Terminal Interface Signal USB 3 USB 3 Data- USB-data signal USB 3 Data+ USB data signal USB 3 USB 4 USB 4 Data- USB-data signal...
  • Page 35: Emc (Electromagnetic Compatibility)

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W Interfaces Ex-i USB 1 and Ex i USB 2 Extension of the USB by use of a protective case (IP20) Only admitted accessories are allowed to connect. (see Chapter Accessories, spare parts) The USB wall bushings on the protective enclosure must correspond at least to protection class IP20.
  • Page 36: Back-Up Fuse

    2.0 A F 1500A@250VAC We recommend protecting the POLARIS with an upstream fuse to prevent blowing the fuse inside the device. Only BARTEC can change the internal fuse. Back-up fuse DC: 4 A quick-acting. The I value is to be observed for other versions of the fuses.
  • Page 37: Interference Suppression

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W 6.7.3 Interference suppression Certain basic measures must be taken to ensure freedom from interference when the POLARIS are installed: The interference voltages coupled into the device via power, data and signal line and the electrostatic voltage caused by contact are to be dissipated through the equipotential bonding.
  • Page 38: Examples Of Shielding Connections

    POLARIS SMART HMI - for Zone 1/21 Installation POLARIS Smart HMI 7” W 6.7.6 Examples of Shielding Connections ATTENTION Device can be damaged by differences in potential! Avoid differences in potential. Double-sided shield connection on the connecting cables: Illustration 7: Example of double-sided shield connection Generally, connection of the shielding at both ends results in optimum damping of all interference frequencies.
  • Page 39: Commissioning

    POLARIS BASIC - for Zone 1 / 21 Commissioning POLARIS Panel PCs 5.7" / 10.4" / 12.1" Commissioning For electrical systems the relevant installation and operating specifications (e.g. Directives 2014/34/EU, BetrSichV and the applicable national ordinances, IEC 60 079-14 and the DIN VDE 0100 series) must be observed.
  • Page 40: Operation

    POLARIS SMART HMI- for Zone 1/21 Operation POLARIS Smart HMI 7” W Operation The device can be put into operation after the final check has been made. The POLARIS series does not have any ON/OFF switch. Operating System The POLARIS series devices have the Windows 7 Embedded MUI, the Windows 7 Ultimate or the Windows 10 IOT operating system pre-installed.
  • Page 41: Commissioning Software

    POLARIS SMART HMI- for Zone 1/21 Operation POLARIS Smart HMI 7” W Commissioning Software Windows 10 IOT The devices are delivered with active writing filter (UWF). This UWF prevents that changes in the disk drive C: can be made. To carry out changes the UWF must be deactivated. Moreover Command Prompt (CMD) must be started as an administrator and „uwfmgr filter disable“...
  • Page 42: Windows 7 Ultimate

    POLARIS SMART HMI- for Zone 1/21 Operation POLARIS Smart HMI 7” W Windows 7 Ultimate By first introduction the operating system must be installed for the user, please follow the instructions on the screen. The Windows 7 Ultimate operating systems do not support EWF! Windows 7 ®...
  • Page 43 POLARIS SMART HMI- for Zone 1/21 Operation POLARIS Smart HMI 7” W Procedure when changing system settings ATTENTION Switching off when the EWF is deactivated can cause a loss of data inside the operating system! Activate the EWF immediately after changes. Shut down the operating system properly.
  • Page 44: Onboard Bartec Recovery Solution

    The Bartec HMI Polaris Smart devices are equipped with an On-Board-Recovery solution. The Bartec Recovery is a software package preloaded on the devices which serves the disregard of the device in the work state. In case of a mistake every device can be booted up in the Recovery mode to move afterwards the operating system into the work state.
  • Page 45: Start Of The Device In The Recovery Mode

    To change in the Recovery mode, one must press the F6 key while booting up the device. This possibility is available for approx. 10 sec. During this time the announcement "Press F6 key to start Bartec Recovery" appears on the screen. ATTENTION...
  • Page 46: Recovery Application

    POLARIS SMART HMI- for Zone 1/21 Operation POLARIS Smart HMI 7” W As soon as the surroundings are completely loaded and are ready for use, the Recovery engine will check in the background whether the applications necessary for the device, tools and drivers exist.
  • Page 47: Restoration In The Work State

    POLARIS SMART HMI- for Zone 1/21 Operation POLARIS Smart HMI 7” W To accept the licence terms, the option "I accept the terms in the End User License Agreement" must be activated or be selected. The button "Start Recovery" is released enclosed.
  • Page 48 POLARIS SMART HMI- for Zone 1/21 Operation POLARIS Smart HMI 7” W ATTENTION With starting the restoration of the operating system in the work state all data on the operating system partition get lost! Contents and format of all other partitions on the hard disk are preserved consistently.
  • Page 49: Finishing The Recovery

    POLARIS SMART HMI- for Zone 1/21 Operation POLARIS Smart HMI 7” W Illustration 15: Prepare the partition After preparing the partition all files from the effigy image stored on the Recovery partition are unpacked and transferred on the operating system partition. Illustration 16: Transferred by system files on operating system partition Transferring of system files is the last process with the Widerherstellung of the operating...
  • Page 50: Recovery/Backup Function

    The POLARIS can be restored to delivery status by means of a recovery stick. The recovery flash drive is not included in the scope of supply. It can be ordered from the contact address www.bartec.de The recovery flash drive contains the functions:...
  • Page 51: Recovery-Stick Image

    Recovery-Stick Image The recovery stick image for the POLARIS SMART HMI can be found on the POLARIS type label. The POLARIS can be restored to the original state only with the BARTEC recovery stick or BARTEC recovery stick image. 8.1.2 Backup We expressly point out that it is the user’s responsibility to make a backup of the...
  • Page 52: Network (Ethernet) Setup

    POLARIS SMART HMI- for Zone 1/21 Operation POLARIS Smart HMI 7” W Network (Ethernet) Setup Requirements Network (Ethernet) setup: Physical connection (connection of Ethernet cable to a network). Go to Start Control panel <double click>. Mark "Network connections" and start with <double click>. Select LAN connection with <...
  • Page 53: Touch Screen

    Configuration example (figure 4) when no DHCP server is available. Figure 3 Figure 4 Touch Screen In the POLARIS with touch screen, the touch screen software is pre-installed already. The touch screen software is available for download under http://www.bartec.de/automation-download/ Technical data subject to change. EN 47/54 04/2018...
  • Page 54: Faults And Troubleshooting

    POLARIS SMART HMI- for Zone 1/21 Faults and troubleshooting POLARIS Smart HMI 7” W Faults and troubleshooting Fault Possible cause Remedy No power supply present Check connection of the power supply External back-up fuse has Check fuse tripped Internal fuse has tripped Return to the manufacturer Nothing is shown on the display...
  • Page 55: Maintenance, Inspection, Repair

    POLARIS SMART HMI - for Zone 1/21 Maintenance, inspection, POLARIS Smart HMI 7” W repair Maintenance, inspection, repair Only trained and qualified personnel may commission and do maintenance work on the POLARIS! Trained qualified personnel are people who are familiar with the installation, assembly, commissioning and operation of the POLARIS, have been instructed about the risks and have the appropriate qualifications by virtue of the work they do.
  • Page 56: Instructions For Repairs

    If you wish to send in a defective device for repair, please read the RMA procedure guidance first. Then fill in and sign the RMA (Return Merchandise Authorisation) form and send it to our "Retouren Center". E-Mail: services@bartec.de Fax: +49 7931 597-119 We cannot guarantee any contractually agreed processing times for devices that are sent in without an RMA number.
  • Page 57: Accessories, Spare Parts

    POLARIS SMART HMI - for Zone 1/21 Accessories, spare parts POLARIS Smart HMI 7” W and order numbers Accessories, spare parts Included in the scope of the delivery: Name Order no. POLARIS Smart HMI 7 Zoll User manual Mounting clamps (assembly-kit with 4 pieces) 05-0091-0260 Reinforcement frame 05-0205-0014...
  • Page 58: Additional Information

    POLARIS SMART HMI - for Zone 1/21 Additional information POLARIS Smart HMI 7” W Additional information Technical data subject to change. EN 52/54 04/2018...
  • Page 59: 16. Declaration Of Conformity

    POLARIS SMART HMI - for Zone 1/21 Declaration of conformity POLARIS Smart HMI 7” W 16. Declaration of conformity Technical data subject to change. EN 53/54 04/2018...
  • Page 60 POLARIS SMART HMI- for Zone 1/21 Declaration of conformity POLARIS Smart HMI 7” W Technical data subject to change. EN 54/54 04/2018...

Table of Contents