Camera menu items (continued)
IP [Off, On]
Sets the UDP output function [On] or [Off] to output tracking data,
such as Pan/Tilt/Zoom or other information from the IP output,
synchronized with the Genlock signal. (→ page 60)
<NOTE>
• When [IP] is [On], video transmission via IP may be delayed or the
video may suffer frame loss.
We recommend setting [IP] to [Off] to avoid the delay or frame loss
due to the video transmission via IP.
• In the following cases, the tracking data output may be delayed or
the value may not be updated.
- When performing video transmission via IP (M-JPEG/H.264/H.265/
RTMP/RTMPS/NDI/NDI|HX/SRT)
- When opening the web screen (live screen [Live] or the web
setting screen [Setup])
- While viewing the OSD menu
- While recalling the preset value during an ongoing preset recall
- When executing AWB/ABB
- When a red or a green tally signal input has been changed
between Off and On
- When deleting a preset memory
- When an output image is flipped (turned upside down or left-right
reversed)
- After switching [Scene]
- After switching [Iris Mode]
- After switching [Super Gain]
- After switching [White Balance Mode]
- After switching [Gamma Mode]
- After switching [Matrix Type]
- After switching [Focus Mode]
- After switching [Zoom Mode]
- After switching [Max Digital Zoom]
- After switching [Digital Extender]
- After switching [Fan]
- After switching [OSD Mix]
- After switching [Tally]
- After switching [Install Position]
- After switching [Preset Speed Unit]
- When executing [Initialize] of [Maintenance]
Invert Pan/Tilt Axis [Off, On]
Sets whether to invert the Pan/Tilt data for output in the tracking data.
Off
Pan/Tilt data is not inverted.
On
Pan/Tilt data is inverted for output.
Return
Return to the previous menu level.

System 2/2 screen

S y s t e m 2 / 2
W i r e l e s s C o n t r o l
F a n
R e t u r n
Wireless Control [Enable, Disable]
[Enable] or [Disable] is set here for operations conducted from the
wireless remote control.
<NOTE>
• When the power is turned on with the wireless remote control, then
operations from the wireless remote control are possible irrespective
of this setting value.
• This item is not reflected immediately when the setting is changed.
It is reflected when the unit is set to Standby mode, and then the
power is turned ON with any external device other than the wireless
remote control.
• This setting is not reflected when the power is turned ON with this
item set to [Enable]. It is reflected when the unit is set to Standby
mode, and then the power is turned ON with any external device
other than the wireless remote control.
Fan [Auto, Low, Mid, High]
Set the operation of the cooling fan.
Auto
Enable automatic control of the cooling fan.
Low
Operate the cooling fan at low speed.
Mid
Operate the cooling fan at medium speed.
High
Operate the cooling fan at high speed.
<NOTE>
• Even if this is set to [Low], [Mid], or [High], the cooling fan may be
forcibly stopped when the temperature is low.
• Even if this is set to [Low] or [Mid], the cooling fan may be forcibly
operated at [High] when the temperature is high.
Return