Web screen configurations (continued)
z SRT
Make SRT transmission settings.
<NOTE>
• When starting SRT transmissions in the [Listener] mode, set the
decoder and application to [Client(Caller)] mode and set the following
URL:
srt://[unit's IP address]:[value set in Client(Caller) port]
• When performing SRT transmissions in the [Client(Caller)] mode,
set the IP address and port number of the decoder and application
to [Destination URI] and [Destination port], and then click the [start]
button for [SRT/MPEG2-TS/RTMP] in the live screen [Live].
• [Passphrase], [Stream ID], etc., can also be specified with options.
Common setup
The setting is confirmed with the [Set] button.
Mode [Client(Caller), Listener]
Selects the method to connect to the SRT compatible decoder or
service.
Client(Caller)
Specify the transmission destination IP address and port
number when starting transmission from this unit.
Listener
Specify the listener port when awaiting the external
request to start transmission.
Factory settings: Listener
Destination URI
When [Client(Caller)] is set in [Mode], enter the IP address.
Images and audio will be sent to the specified IP address.
Factory settings: 192.168.0.3
<NOTE>
• Only IPv4 can be set as the IP address.
Destination port [1 to 65535]
When [Client(Caller)] is set in [Mode], enter the port number (used
when transmitting images from this unit).
Connection is to the specified port number.
Factory settings: 7002
<NOTE>
• The following port numbers are used by the unit so they cannot be
used.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 546,
547, 554, 995, 5960 to 5985, 7960 to 8060, 10669, 10670, 11900,
59000 to 61000
Stream ID
When [Client(Caller)] is set in [Mode], enter the Stream ID.
The information entered is notified to the connection destination when
SRT transmission is started.
If the [InsertTemplate] button is clicked, the following template is
inserted in the input fields.
#!::m=publish,r=PanasonicStream
• The following characters can be displayed.
Numeric characters
Alphabetical
characters
(upper and lower
cases)
Symbols
Factory settings: #!::m=publish,r=PanasonicStream
Client(Caller) port [1 to 65535]
When [Listener] is set in [Mode], enter the port number (used when
this unit is waiting for a connection).
The following port numbers are used by the unit so they cannot be
used.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 546,
547, 554, 995, 5960 to 5985, 7960 to 8060, 10669, 10670, 11900,
59000 to 61000
Factory settings: 2020
TTL/HOP Limit
The same as H.264 [Multicast TTL/HOPLimit] (→ page 104).
<NOTE>
• When streaming SRT via a public network, it is recommended to
change the TTL setting to a suitable value (64, etc.).
Latency
Sets the time between when images and audio are sent and when
they are played on the receiving device in a range between 0 and
99999 (ms).
Factory settings: 120
<NOTE>
• In some cases, the set time is not guaranteed depending on the
network band.
Encryption [Off, AES‑128, AES‑256]
Sets whether to encrypt the transmitted IP image.
Off
Transmits unencrypted IP images.
AES-128
Encrypts IP images in AES-128 before transmitting.
AES-256
Encrypts IP images in AES-256 before transmitting.
Factory settings: Off
• The following characters can be displayed.
Numeric characters
Alphabetical
characters
(upper and lower
cases)
Symbols
Passphrase
Sets the phrase used for decoding the encrypted IP images.
(10 to 24 characters)
106
0123456789
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
!"#$%'()=-~^¦\`@[]{}
:+;<>,.?/\_
*