Camera menu items (continued)
Rise Ramp Time [0.1s to 10.0s]
Sets the acceleration time for the time specific operation during preset
playback. (Sets between 0.1 s to 10.0 s in 0.1 s increments)
This is enabled only when [Preset Acceleration] is [Manual] and
[Preset Speed Unit] is [Time].
<NOTE>
• As the time specified in [Preset Speed] takes precedence as the
total time for preset playback, if the time specified here is more than
half of the time specified in [Preset Speed], this functionality will not
operate as specified.
• When the acceleration operation cannot be performed within the
specified time even at maximum acceleration speed of the device,
the operation will not be performed by the specified time.
The relationships between the various setting values when [Preset Acceleration] is set to [Manual]
during preset playback
z When [Preset Speed Unit] is [Speed Table]
It is possible to specify the responsiveness (maximum speed, acceleration rate, S-curve steps) for operation.
<NOTE>
• When the amount of movement specified by the preset is small, there may be cases when the specified speed is not reached.
• Restrictions are automatically placed on the acceleration rate to prioritize the specified speed. (The lower limit of the acceleration rate is automatically
restricted by the specified speed.)
• To enable the pan and tilt operations to occur simultaneously, the maximum speed of the axis with a smaller amount of movement is automatically
restricted.
Acceleration
range
[Rise S‑Curve]
0 to 30
Acceleration time
[Rise Acceleration]
1 to 255
The larger the value, the shorter the
acceleration time
(It takes less time to reach the speed
specified with preset pan/tilt operation)
Range during which the speed reaches the maximum
according to that specified by preset operation of pan/tilt
The larger that the value of the S-curve is, the greater
the speed changes when accelerating or decelerating
(represented by the dotted line rather than the solid line), and
the operational feel of acceleration and deceleration changes.
There is no change in the time taken for accelerating or
decelerating with the S-curve setting.
The time taken to move to the destination from
when the preset is started
Fall Ramp Time [0.1s to 10.0s]
Sets the deceleration time for time specified operations during preset
playback. (Sets between 0.1 s to 10.0 s in 0.1 s increments)
This is enabled only when [Preset Acceleration] is [Manual] and
[Preset Speed Unit] is [Time].
<NOTE>
• As the time specified in [Preset Speed] takes precedence as the
total time for preset playback, if the time specified here is more than
half of the time specified in [Preset Speed], this functionality will not
operate as specified.
• When the deceleration operation cannot be performed within the
specified time even at maximum fall deceleration of the device, the
operation will not be performed by the specified time.
Return
Return to the previous menu level.
[Fall S‑Curve]
0 to 30
[Fall Acceleration]
The larger the value, the shorter the
deceleration time
(It takes less time to reach the
deceleration or stopped status specified
with preset pan/tilt operation)
68
Deceleration
range
Maximum speed reached
(Speed specified with
[Preset Speed])
Deceleration
time
1 to 255