Web screen configurations (continued)
z Genlock
This item is selected to perform the phase adjustments.
This item's setting is reflected immediately.
Horizontal Phase [–206 to +49]
This is used to adjust the horizontal phase during genlock.
Factory settings: 0
z Wireless Control
Wireless Control [Enable, Disable]
[Enable] or [Disable] is set here for operations conducted from the
wireless remote control.
The setting is confirmed with the [Set] button.
Factory settings: Enable
<NOTE>
• When the power is turned on with the wireless remote control, then
operations from the wireless remote control are possible irrespective
of this setting value.
• This item is not reflected immediately when the setting is changed.
It is reflected when the unit is set to Standby mode, and then the
power is turned ON with any external device other than the wireless
remote control.
• This setting is not reflected when the power is turned ON with this
item set to [Enable]. It is reflected when the unit is set to Standby
mode, and then the power is turned ON with any external device
other than the wireless remote control.
z Fan
Set the cooling fan operation.
The setting is confirmed with the [Set] button.
<NOTE>
• Even if this is set to [Low], [Mid], or [High], the cooling fan may be
forcibly stopped when the temperature is low.
• Even if this is set to [Low] or [Mid], the cooling fan may be forcibly
operated at [High] when the temperature is high.
Fan [Auto, Low, Mid, High]
Set the operation of the cooling fan.
Auto
Enable automatic control of the cooling fan.
Low
Operate the cooling fan at low speed.
Mid
Operate the cooling fan at medium speed.
High
Operate the cooling fan at high speed.
Factory settings: Mid