Web screen configurations (continued)
OSD Status [Off, On]
Turn the status display during AWB and ABB off/on, or error display
when an error occurs.
Factory settings: Off
Tally [Disable, Enable]
[Disable] or [Enable] is set here for the function which turns on or
turns off the tally lamp using the tally control signal.
Factory settings: Enable
Tally LED Limit
Sets whether to limit the lighting of the tally lamp for each of the tally
control signal colors (R/G).
R [Limit, Unlimit
]
*
G [Limit, Unlimit
]
*
Limit
Limit the lighting of the tally lamp.
Unlimit
Light the tally lamp.
: Factory settings
*
<NOTE>
• If [Disable] is selected for [Tally], the tally status display on external
devices (the web screen, controllers such as AW-RP150 and
AW-RP60) is also disabled along with the limiting of the tally lamp
lighting on this unit.
• If [Limit] is selected for [Tally LED Limit], only lighting of the tally
lamp of this unit is limited. The tally status display on external
devices (the web screen, controllers such as AW-RP150 and AW-
RP60) remains enabled.
Tally Brightness [Low, Mid, High]
Adjust the brightness of the tally LED.
Factory settings: Low
Status Lamp [Disable, Enable]
[Disable] or [Enable] is set here for the status display lamp.
When you want the status display lamp to stay off while this unit is in
operation, set to [Disable].
Factory settings: Enable
<NOTE>
• Even when set to [Disable], the status display lamp may light
up when this unit is starting up, updating firmware, or trouble is
occurring.
External Output
Select the signal type output from the External Output signal lines
(Output1, Output2) of the RS‑422 connector. (→ page 17)
Output1 [Off
, R‑Tally, G‑Tally]
*
Output2 [Off
, R‑Tally, G‑Tally]
*
Off
Signal is not output.
R-Tally
The reception status of the red tally signal is output.
G-Tally
The reception status of the green tally signal is output.
: Factory settings
*
z Pan/Tilt
The setting is confirmed with the [Set] button.
Install Position [Desktop, Hanging]
[Desktop] or [Hanging] is selected here as the method used to install
the unit.
Desktop
Stand-alone installation
Hanging
Suspended installation
Factory settings: Desktop
<NOTE>
• When [Hanging] has been selected, the top, bottom, left and right
of the images will be reversed, and up/down/left/right control for
panning and tilting will also be reversed.
P/T Speed Mode [Normal(60deg/s), Fast1(90deg/s),
Fast2(180deg/s)]
Set the speed of pan/tilt operation.
Normal(60deg/s)
Pan/tilt operates at normal speed (maximum about
60° per second).
Fast1(90deg/s)
Pan/tilt operates at fast speed1 (maximum about 90°
per second).
Fast2(180deg/s)
Pan/tilt operates at fast speed2 (maximum about
180° per second).
Factory settings: Normal(60deg/s)
P/T Acceleration Setting
P/T Acceleration [Manual, Auto]
Sets whether to perform advance setting for acceleration and
deceleration etc. during manual operation of pan/tilt.
Manual
Sets the advanced settings for acceleration speed
etc. during start/stop or changing the speed of pan/tilt
operation.
Auto
Sets the settings for automatic acceleration and
deceleration speed etc. during start/stop or changing the
speed of pan/tilt operations.
Factory settings: Auto