Fujitsu PRIMERGY TX1320 M5 Upgrade And Maintenance Manual page 85

Table of Contents

Advertisement

▶ Enter the command below, followed by [ENTER]:
<CPU#> parameters are "0" for CPU 1 and "1" for CPU 2.
For rack and floorstand servers (RX and TX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#>
For blade and scale-out servers (BX and CX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#> cab=<cabinet nr>
To identify the cabinet number, enter the following command:
/usr/sbin/eecdcp -c oc=E204
If the error status cannot be reset with the method above, please use the
following procedure for resetting the error counter of all CPUs:
▶ Log in as root.
▶ Enter the commands below, followed by [ENTER]:
1. /etc/init.d/srvmagt stop
/etc/init.d/srvmagt_scs stop
/etc/init.d/eecd stop
/etc/init.d/eecd_mods_src stop
2. cd /etc/srvmagt
3. rm -f cehist.bin
4. /etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
Using Infrastructure Manager
The status of server (node) which failed CPU is installed becomes error.
When replacing the CPU, the status will be updated after getting information
manually or automatically updated daily.
TX1320 M5
Upgrade and Maintenance Manual
Basic software procedures
85

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents