INSTALLING THE OPTIONAL FAN

Important: 120 Volt AC power is needed for the
blower. The receptacle box will be installed on
the left hand side of the unit and will need to
be wired by a qualified electrician prior to fan
assembly being installed. The neutral (wider)
slot of the polarized receptacle should be at the
top. The A/C Adapter supplied with the unit
is not required and should be disconnected
when using the GTMF Module. The Module
will provide power to operate the system.
Unit must be grounded at all times. Do not
cut the ground terminal off under any
circumstances.
1. Shut the power off.
2. Remove the mesh barrier and standard
flush door.
3. Turn the fan base on its side (with the base
facing towards you) and then slide the fan
in towards the rear of the unit. Turn the fan
upright and slip it over the two mounting
studs. Take care not to damage the insula-
tion on the fan base. Ensure that the fan
blades do not rub against the valve tubing.
Diagram 2
4. Connect fan ground cable to ground lug. Refer
to wiring diagram.
Mounting Pins
Electrical
Receptacle
Push Fan down
on mounting pins
Ground Lug
Plug fan power cord
into
receptacle.
rear
919-424
FAN INSTALLATION
5. Slide the thermodisc/cover assembly into
the bracket clip on the underside of the
firebox. Check that no wire will touch the
hot surfaces. Diagram 3 and 4.
Diagram 3
Diagram 4
6. Install the Fan Control Module (FCM) on to
the left side base of the unit and plug in to
electrical receptacle in unit as shown.
1
B36XTCE / B36XTE
installation
7. Plug in the fan power cord to the Fan Con-
trol Module into the outlet marked "Fan".
Disconnect the A/C adapter from the
FC-COM wire (If installed) and remove.
Plug the FCM-COM wire from the remote
control wiring harness into the location on
the Fan Control Module marked "COM".
Turn the switch on the Fan Control Module
to the ON position. ON is to the left. The "O"
is the off position.
FCM-COM Wire
Fan Power Cord
FCM-COM wire
8. See the Proflame instructions for coding the
remote handheld to the receiver and for
operating instructions.
9. Reverse Steps 2 -1 to complete the instal-
lation.
TO REMOVE THE FAN
1) Shut the power off.
2) Reverse the above instructions.
Note: The bearings are lubricated for life.
Do not lubricate them. Make sure you
vacuum the fan area on a regular basis.
IMPORTANT:
These fans collect a lot of dust from within
your home. Ensure you maintain these fan
motors on a regular basis by vacuuming
out the fan blades and housing using a soft
brush nozzle.
Bellavista® B36XTCE-11 Gas Fireplace
|