FRAMING

Framing Dimensions
M
N
O (Rear Vent)
O (Top Vent)
P (Top Vent)
P (Rear Vent)
Q (Top Vent)
Q (Rear Vent)
R (Rear Vent)
R (Top Vent)
S (Rear Vent)
S (Top Vent) (5" x 8")
S (Top Vent) (4" x 6-5/8")
T
U
V
W
X
** Important: Framing height requires consideration of the hearth depth. Dimension N = N + the thickness of the installed hearth.
Non-combustible
Header
(steel stud
on edge)
X
N
Description
Framing Width
Framing Height
Framing Depth - Rear Vent
Framing Depth - Top Vent
Corner Facing Wall Width
Corner Facing Wall Width
Corner Facing Wall Width
Corner Facing Wall Width
Framed Chase Ceiling - Rear
Framed Chase Ceiling - Top
Vent Centerline Height - Rear
Vent Centerline Height - Top
Vent Centerline Height - Top
Gas Connection Height
Gas Connection Inset
Gas Connection Width
Non-combustible Height
Optional steel stud
M
P
Q Q
B36XTCE
41-1/4"(1048mm)
46-3/4" (1213mm)
23-7/8" (606mm)
23-7/8" (606mm)
53-1/4" (1353mm)
57-7/8" (1470mm) AstroCapXL
66-1/8" (1680mm) - other approved caps
75-1/4" (1911mm)
81-1/2" (2070mm) AstroCapXL
93-1/2" (2375mm) - other approved caps
47-3/4" (1213mm)
50-1/2" (1283mm)
26-1/2" (673mm)
42-1/8" (1070mm) Flex
44-1/4" (1123mm) Rigid
-
1-1/2" (38mm)
7-3/8" (187mm)
3-1/4" (83mm)
9-1/4" (235mm)
41'' (1041 mm)
R
Drywall
(or other
facing)
Non-Combustible
Header
(steel stud) on edge
W
Non-Combustible Facing
11" (279mm)
dia. Hole through
wall Vent.
O
S
T
U V
Opening for gas
connection
49" (1245mm) Rigid
S
Bellavista® B36XTCE-11 Gas Fireplace
installation
|