installation
HORIZONTAL TERMINATIONS
FLEX VENT 5" X 8"
These venting systems, in combination with the B36XTCE Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by
Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations Diagram in "Exterior Vent Termination
Locations" section.
Regency
Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615) includes all the parts needed to install the B36XTCE with a either
®
a top or rear vent.
Note: If top venting this unit, the 5" x 8" venting may only be used if venting to the minimum of 42-1/3" to center line.
No other application is approved.
FPI Kit #
Length Contains:
#946-615
4 Feet
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. vinyl siding standoff
1. 8" dia. flexible liner (4 ft. length)
2. 5" dia. flexible liner (4 ft. length)
3. spring spacers (4)
4. thimble
5. AstroCapXL termination cap (1)
6. screws (12)
7. tube of Mill Pac (1)
8. plated screws (8)
9. screws #8 x 1-1/2" Drill Point,
Stainless Steel (4)
10. vinyl siding standoff
Notes:
1. Liner sections should be continuous without any joints or seams.
2. Only Flex pipe purchased from Regency may be used for Flex installations.
3. Regency® Direct Vent System (Flex) is only approved for horizontal terminations.
|
38
Bellavista® B36XTCE-11 Gas Fireplace
8" flexible liner (Kit length)
5" flexible liner (Kit length)
spring spacers
thimble
AstroCap termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 1-1/2" drill point