Installation Checklist; Locating Your Gas Fireplace - Regency Bellavista B36XTCE Owners & Installation Manual

Hide thumbs Also See for Bellavista B36XTCE:
Table of Contents

Advertisement

INSTALLATION
CHECKLIST
1. Locate appliance
a) Room location (Refer to "Locating Your
Gas fireplace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Combustible
Mantel Clearances" section)
d) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2. Assemble Top Standoffs and Top Facing
Support and Side Nailing Strips (Refer to
"Unit Assembly Prior to Installation" Section).
NOTE: Must be done before installing unit
into place.
3. Install vent (Refer to "Venting" sections).
4. Make gas connections. Test the pilot. Must be
as per Diagram (Refer to "Pilot Adjustment "
section).
Convert to propane if desired (Refer to "Gas
Line Installation" and "Conversion Kit from
NG to LPG" sections).
5. Make electrical connections to receptacle
supplied with unit (recommended).
6. Install standard and optional features. Refer
to the following sections:
a. Install 4AA batteries into battery pack or
install supplied AC power adaptor
b. Inner Panels or Brick Panels (Optional)
c. Log Set Installation
d. Standard Flush Door
e. Fan Installation (Optional)
7. Final check.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label 31,000 Btu/h
for natural gas and propane), after burning
appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
LOCATING YOUR
GAS FIREPLACE
1. When selecting a location for your fireplace,
ensure that the clearances are met.
2. The appliance must be installed on a flat,
solid, continuous surface For example a
wood, metal or concrete floor or in a raised (on
the wall) application. The appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.
3. The B36XTCE Gas Fireplace can be installed
in a recessed position or framed out into the
room as in A, B, C and D. See Diagram 1.
Diagram 1
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
owner's information
4. This appliance is Listed for bedroom instal-
lations using the standard Remote (millivolt
thermostat system). Some areas may have
further requirements, check local codes before
installation.
5. The B36XTCE Gas Fireplace are approved for
alcove installations, see "Clearances" section
for details.
6. We recommend that you plan your installa-
tion on paper using exact measurements for
clearances and floor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.
Note: F o r v e n t t e r m i n a t i o n s r e fe r
to "Exterior Vent
Locations" section.
Bellavista® B36XTCE-11 Gas Fireplace
Termination
|
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

B36xtce-11Bellavista b36xtce-11