Important:
Incorrectly wired connections will produce a short
circuit later on in the product or your fuse box. In
this case, you must identify the individual conduc-
tors once again and re-connect them. A mains
power switch for turning the unit ON and OFF may
of course be installed in the mains supply lead.
Note:
The light source in this light must only replaced by
the manufacturer or a service engineer authorised
by the manufacturer or by a similarly qualified
person.
Connecting the mains power supply lead (Fig. 5.6)
L 240 S, L 220 S wiring diagram (Fig. 4.2)
L 240 S, L 220 S wiring diagram (Fig. 4.3)
5. Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, giving
consideration to sensor reach and mounting
height (Fig. 5.1).
Mounting procedure
(Based on the example of L 220)
• Switch OFF power supply (Fig. 4.1).
• Detach light housing from the wall mount, paying
attention to the position of the sensor (Fig. 5.2).
• Mark drill holes (Fig. 5.3).
• Drill holes and insert wall plugs (concealed power
supply cable (Fig. 5.4).
• Drill holes and insert wall plugs (with spacers for
surface power supply cable (Fig. 5.5).
• Connect conductors (Fig. 5.6).
• Connect plug-in connectors (Fig. 5.7).
• Fit light enclosure (A) onto wall mount (C). Pay
attention to plug-in connections as well as the
position of the sensor (Fig. 5.8).
• Screw light enclosure into place (Fig. 5.9).
• Switch ON power supply (Fig. 5.10).
• Make settings (S only) ➔ "6. Functions".
6. Functions
The sensor-switched light can be put into service
after mounting the light enclosure and connecting
to the mains power supply.
Factory settings (S only)
Twilight setting: daylight operation 2000 lux
Time setting: 8 s
Twilight setting / response threshold (S only)
(Fig. 6.1)
– The sensor's response threshold can be infinitely
varied from 2–2000 lux.
– Control dial set to
approx. 2000 lux.
– Control dial set to
approx. 2 lux.
Time setting (S only) (Fig. 6.1)
– Light ON duration can be infinitely varied from
8 s - 35 min
– It is recommended that the shortest time be
selected for setting the detection zone.
– Control dial, shortest time = approx. 8 s
– Control dial, longest time = approx. 35 min
Adjusting the detection zone / reach setting
(S only)
– Depending on the mounting height, the detection
zone setting can be optimised to suit require-
ments. The shroud foil can be used for masking
out any number of lens segments to limit reach
as required, e.g. to mask out paths or neigh-
bouring property (Fig. 6.2).
– Reach can be adjusted from 2-10 m by tilting
the sensor (D) through 90° (Fig. 6.3).
House numbers
• Affix the house street number using the stickers
provided (Fig. 6.4).
7. Maintenance / care
Warning of hazards from electricity!
Contact between water and live parts can result in
an electric shock, burns or death.
• Only clean device in a dry state.
Risk of damage to property!
Using the wrong cleaning product can damage the
light.