Maintenance And Care; Manufacturer's Warranty - STEINEL Professional Series Instructions Manual

Hide thumbs Also See for Professional Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
Twilight setting (controller 
The chosen response threshold can be infinitely varied
from approx. 2 to 1000 lux.
– Control dial set to
on ambient brightness)
– Control dial set to
To adjust the detection zone in daylight operation, the
control dial must be set to
Time setting (controller 
The light's ON time can be set to any period from
approx. 5 seconds to a maximum of 15 minutes. Any
movement detected before this time elapses will restart
the timer.
Manual override function
If a mains switch is installed in the mains supply lead,
the following functions are available in addition to
simply switching light ON and OFF:
Sensor operation
1) Switch light ON (when light is OFF):
Switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON):
Switch OFF and ON once.
Light goes out or switches to sensor operation.
6.4
Manual override (Fig. 
1) Activate manual override:
Switch OFF and ON twice. The light is set to stay ON
for 4 hours (red LED lights up behind the lens). Then it
returns automatically to sensor operation (red LED off).
2) Deactivate manual override:
Switch OFF and ON once. Light goes out or switches
to sensor operation.
Important:
Switching must take place within 0.2 to 1 second.
Adjusting the detection zone (Fig. 
The detection zone can be limited to suit requirements.
The shrouds supplied with the unit can be used to
mask out as many lens segments as you wish. This
prevents the light from being activated unintentionally,
e.g. by cars, passersby etc., and allows you to target
danger spots. The shrouds can be cut along the
grooved vertical divisions. Then you simply clip them
onto the lens.
The light can be operated without sensor. To do this,
simply replace the sensor unit with the sealing plug.
6.3
(Fig. 
)
The light can be switched ON and OFF at a mains
switch in the mains supply lead.
6.2
/G)
= daylight mode (depending
= twilight mode (approx. 2 lux)
(daylight operation).
6.2
/E)
)
6.5
6.9
-
)

7. Maintenance and care

The product requires no maintenance.
The light can be cleaned with a damp cloth (without
detergents) if dirty.
Important note: the control gear cannot be replaced.
8. Disposal
Electrical and electronic equipment, accessories and
packaging must be recycled in an environmentally
compatible manner.
Do not dispose of electrical and electronic
equipment as domestic waste.
EU countries only:
Under the current European Directive on Waste Elec-
trical and Electronic Equipment and its implementation
in national law, electrical and electronic equipment no
longer suitable for use must be collected separately
and recycled in an environmentally compatible manner.

9. Manufacturer's Warranty

As purchaser, you are entitled to your statutory rights
against the vendor. If these rights exist in your country,
they are neither curtailed nor restricted by our Warranty
Declaration. We guarantee that your STEINEL Profes-
sional sensor product will remain in perfect condition
and proper working order for a period of 5 years. We
guarantee that this product is free from material-, man-
ufacturing- and design flaws. In addition, we guarantee
that all electronic components and cables function in
the proper manner and that all materials used and their
surfaces are without defects.
Making Claims
If you wish to make a claim, please send your product
complete and carriage paid with the original receipt of
purchase, which must show the date of purchase and
product designation, either to your retailer or contact
us at STEINEL (UK) Limited, 25 Manasty Road, Axis
Park, Orton Southgate, Peterborough, PE2 6UP, for
a returns number. For this reason, we recommend that
you keep your receipt of purchase in a safe place until
the warranty period expires. STEINEL shall assume
no liability for the costs or risks involved in returning a
product.
– 16 –

Advertisement

Table of Contents
loading

This manual is also suitable for:

L 330 sL 331 s40078410530934007841053079

Table of Contents