6. Function and settings
The sensor is put into operation in
accordance with the applicable DALI 2
standard. All functions and commands
of the DALI standard IEC 62386 Part
101, Part 103, Part 303 and Part 304 are
available.
– The motion detection values and light
levels measured by the sensor can be
requested from the DALI Application
Controller.
– Automatic or time-based cyclical
transmission can also be selected.
You will find detailed information in the
interface description on the Internet at:
www.steinel.de
LED function
Initialisation: LED flashes blue
Normal mode: LED OFF
Error: LED lights up red
Programming mode:
LED lights up turquoise
Test mode, movement:
LED permanently lights up green
Test mode, no movement:
LED permanently lights up red
Identification via DALI:
LED flashes magenta
Setting Hallway detection DALI-2 IPD
The reach and sensitivity can be set
separately for both directions. The Steinel
logo on the sensor serves as a reference
here (Fig. 6.1).
Example:
A
The reach shown by "S" in the
interface description points to
the direction in which the S in the
Steinel logo points.
B
The reach shown by "L" in the
interface description points to
the direction in which the L in the
Steinel logo points.
You will find detailed information in the
interface description on the Internet at:
www.steinel.de

7. Maintenance and care

Hazard from electrical power!
Contact between water and live parts
can result in electrical shock, burns or
death.
• Only clean tool in a dry state.
Risk of damage to property!
Using the wrong detergent can damage
the light.
• Clean unit with a moist cloth without
detergent.

8. Troubleshooting

Light does not switch ON.
– No supply voltage.
• Check supply voltage.
– No presence detection.
• Ensure unobstructed sensor vision.
• Check detection zone.
Lights do not switch OFF.
– Objects moving in the detection zone.
• Check detection zone.
Sensor switches OFF despite persons
being present.
– Reach set too low.
• Change reach.