Setting of the the reaction of outputs to the communication error
1) Set the value of the following instance/ attribute to 1.
Class
64h
(SMC)
2) Set the fault action and fault values in the following instances.
There are two types of fault setting method, one is the individual setting per point with DOP Object
and the other one is the batch setting with Assemble Object.
Individual setting per point:
Fault setting
Fault
action
Fault
value
Note: For details, refer to the DeviceNet Objects section.
Batch setting for all outputs:
Fault setting
Fault
action
Fault
value
Note: For details, refer to the DeviceNet Objects section.
Diagnostic information
The status of the load voltage for the valve is mapped in the input data using vendor specific area of the
Assembly Object instance
Note: For details about Assembly Object, refer to the DeviceNet Objects section.
Function
Valve power supply voltage
monitoring
Data format of the diagnostic information is as follows. (Other than bit 2 value is alwayd fixed to zero)
Assembly Object Instance Data format (vendor specific)
ID
105
(Diagnostic
Status)
Instance
attribute
68h(104)
01h(01)
Class
Instance
09h
(Output
(DOP)
numer+1)
Class
Instance
04h
(Assembly)
Check if the load power for the valve is not supplied
or outside tolerance range (19V or less)
Byte
offset
7
6
+0
0
0
SOLV Status
0: Valve power supply
voltage is normal.
1: Valve power supply
voltage is abnormal.
Description
Hold Clear Timuout
Description
n
05h
06h
Description
66h
03h
65h
03h
Description
Bit
5
4
0
0
‑17‑
Value
0: Switch setting valid
1: EEPROM set value Valid
Value
0
Fault value
:
1: Output held
0: CLEAR
1: SET
Value
0
Fault value
:
1: Output held
0: CLEAR
1: SET
3
2
1
X
0
0
0
0
EX##‑OMN0013