INTRODUCTION

2.2 INDICATORS AND KEYPAD BUTTON

1
The following LED indicators are located on the reader:
blue LED indicates that the reader is connected to the power supply (Figure 17, 1)
POWER
yellow LED indicates connection to the on-board Ethernet network (Figure 17, 2)
NET
In normal operating mode the colors and meaning of the five LEDs are illustrated in the
following table:
green LED indicates that the reader is ready to operate (Figure 17, 3)
READY
green LED confirms successful reading (Figure 17, 4)
GOOD
yellow LED indicates the status of the reading phase (Figure 17, 5)
TRIGGER
yellow LED indicates active communication on the main serial port * (Figure 17, 6)
COM
red LED indicates a NO READ result (Figure 17, 7)
STATUS
* When connected to a Fieldbus network through the CBX500, the COM LED is always active, even in
the absence of data transmission, because of polling activity on the Fieldbus network.
During the reader startup (reset or restart phase), these five LEDs blink for one second.
In X-PRESS™ Configuration mode the colors and meaning of these five LEDs are described
in par. 2.5.
The keypad button (Figure 17, 8), is software programmable. By default it starts the
X-PRESS™ interface for quick installation without using a PC (see chp. 1).
2
8
Figure 17 - Indicators
7
6
5
4
3
2
23