Troubleshooting Guide - Taylor C850 Series Equipment Manual

Clamshell grill for mcdonald's
Hide thumbs Also See for C850 Series:
Table of Contents

Advertisement

Troubleshooting Guide

WARNING: Improper installation, adjust­
ment, alteration, service or maintenance can
cause property damage, injury or death. Read
the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
WARNING: Inspection, testing, and repair of
electrical equipment should be performed only by
qualified service personnel.
The grill should be disconnected from all
electricity when servicing, except when electrical tests
are required.
Equipment Troubleshooting
PROBLEM
The exhaust hood alone does not
turn on when the fan interlock
switch in the ON position.
The grill alone will not turn on when
the fan interlock switch is in the
ON position.
The platen will not stay down when
the Standby button is pressed.
The grill displays "TOO COOL".
The grill displays "TOO HOT"
circuit tests. Live circuitry may be exposed.
thorough cleaning. When returning the grill to its
original position, use extreme caution to smoothly and
slowly roll the grill backward into place. Failure to do
so may cause the grill to tip, and will cause severe
equipment damage or personal injury.
ENTIRE GRILL (ALL MODELS)
PROBABLE CAUSE
The fan interlock switch is faulty.
Loose or broken wires to switch.
The grill breaker has tripped.
The grill's control voltage cord has
become unplugged.
The Ansul reset tripped.
Internal component failure
The cavity where the handle
latches to the latch solenoid (This
is located at the front of the grill.) is
dirty.
Internal component failure
The grill is not within the specified
temperature range of the specified
recipe.
3 phase breaker tripped.
3 phase cord has become
unplugged from the wall.
The grill is not within the specified
temperature range of the specified
recipe.
56
DANGER: Use extreme care during electrical
The grill must be pulled away from the wall for
REMEDY
Call for service.
Call for service.
Reset the breaker.
Reseat the power cord.
Press the Ansul reset button.
If the problem still remains, call for
service.
Clean the handle foot and/or the
latch solenoid post.
If the problem still remains, call for
service.
Wait for the grill to reach
temperature range for specified
recipe.
Reset the breaker.
Reseat the 3 phase plug.
Wait for the grill to reach
temperature range for specified
recipe.

Advertisement