GE DigitalFlow DF868 Programming Manual page 29

Panametrics multipurpose ultrasonic liquid flowmeter
Hide thumbs Also See for DigitalFlow DF868:
Table of Contents

Advertisement

Calibration Factor
Programming Site Data
14.Enter a value for the flow Calibration Factor and press
default value is 1.00, but values between 0.50 and 2.00 may be
entered.
15.The menu now varies, depending on whether you have activated
the TransFlection or Transit-Time mode.
If you activated the TransFlection mode, the program asks for the
Depth of Reflector. This setting determines where in the pipe the
DF868 looks for the reflected signal. The default value is 50%.
Use the numeric keys to enter a value, and press
Note: The factory recommends activating the Reynolds Correction
Factor when the Depth of Reflector is set at 50%. You can
disable the Reynolds Correction Factor when the Depth of
Reflector is set at any other value.
If you activated the Transit-Time mode, two steps appear.
[F1]-[F4]
a. Use the
keys to select the desired Number of
Traverses, the number of times the ultrasonic signal traverses
the pipe, from 1 to 5.
b. The Transducer Spacing prompt displays the spacing of the
transducers, as calculated from the information you have
entered. Record this number and use it to properly space
transducers.
Note: If necessary, you can overwrite the spacing shown (using the
numeric keys) to match the actual physical spacing of the
transducers. The factory does not recommend overwriting the
spacing. If you must, do not change the spacing by more than
±10% from the value shown.
You have completed entering pipe parameters for clamp-on
[ENT]
transducers. Press
to return to the start of the
[EXIT]
to leave the submenu. Table 1-11 below lists the numeric
PIPE
parameters in the
submenu, with their high and low limits.
Table 1-11: Low and High Limits for PIPE Parameters
Parameter
Wedge Angle
Pipe OD
Pipe Wall
Lining Thickness
Kinematic Viscosity
Path Length
Axial Length
[ENT]
PIPE
Low Limit
High Limit
25°
0.12 in.
0 in.
0 in.
0.1
10,000 (E-6 ft
0.12 in.
0.12 in.
March 2008
[ENT]
. The
.
submenu, and
90°
300 in.
4.0 in.
4.0 in.
2
/s)
480 in.
480 in.
1-21

Advertisement

Table of Contents
loading