Xerox WorkCentre 3215 Service Manual page 166

Hide thumbs Also See for WorkCentre 3215:
Table of Contents

Advertisement

Data Setup
The following items can be modified:
Send Level
The level of the transmission signal (Tx). The Tx signal can be set to a value between
9dBm and 15 dBm. Normally, the Tx level should be less than 12 dBm.
DTMF Level
The value of the High level tone and the Low level tone in DTMF mode. (Not dial mode).
Both High and Low can be set to a value between 0 and 15.
Pause Time
The delay time when receiving the pause input at auto dial. The pause time can be set to
a value between 1 and 9 seconds.
Dial Mode
The type of dial method, either Dial or Pulse. The default setting is Dial.
Modem Speed
The modem speed is automatically set to a slower speed when communicating with a
slower speed modem, as communication is done on the standard of the side where
modem speed is low for transmission/reception. Available settings are 33.6 Kbps, 28.8
Kbps, 14.4 Kbps, 12.0 Kbps, 9.6 Kbps, and 4.8 Kbps. It is recommended to maintain the
default setting of 33.6 Kbps.
Error Rate
When the error rate is about exceed the set value, the Baud rate automatically adjusts to
2400 bps. This ensures that the error rate remains below the set value. The error rate can
be set to 5% or 10%.
Clear All Memory
To reset the system to factory default settings when the product is functioning abnormally.
All system settings are returned to the default values, including all customer settings.
NOTE: Clear All Memory must be performed after replacing the Main PWB. Failure to do
so could negatively effect machine performance.
Toner Low Level
This is used to set up when the customer is notified to replace the Toner Cartridge. The
time can be set to 1-30%.
ImgU Low Level
This is used to set up when the customer is notified to replace the Imaging Unit?. The
time can be set to 1-50%.
Clear Count
Use this to reset the copy counters for the following operations or components:
ADF Scan
Platen Scan
Transfer Roller
Pickup Roller
Retard Roller
Forward Roller
NOTE: A password is required to reset these counters.
General Procedures and Information
Data Setup
Engine Footer
This function is used to display the print engine status on the bottom of a printed page. It
is set to either On or Off. The default setting is Engine footer Off.
Dial Tone
The dial tone feature can be set to on or off.
Caller ID
The caller ID feature can be set to on or off.
Busy Tone
The busy tone feature can be set to on or off
Firmware Upgrade
The F/W Upgrade feature can be set to on or off.
Set Serial Number
The Set Serial Number feature is used to manually input the machine serial number after
replacing the Main PWB.
Format Flash
The Format Flash feature clears the flash memory which is allocated to store fonts.
June 2014
6-24
Xerox® WorkCentre® 3215/3225 Multifunction Printer Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 3225

Table of Contents