Install The Control; Install Auxiliary Mounting Pad - Danfoss 45 K2 Series Repair Instructions

Axial piston open circuit pumps
Table of Contents

Advertisement

Repair Instructions
Series 45 Frame K2 Axial Piston Pumps
Reassembly

Install the control

Install auxiliary mounting pad

34 |
©
Danfoss | April 2017
Item
Description
QC125
Coil plastic nut
C300
Screws
1. Using petroleum jelly to retain them, install 4 new seal rings (C200) in the recesses on the control
housing.
2. Install the control assembly onto the endcap using the 4 screws (C300). Torque at 5.4 to 7.5 N•m [4.0
to 5.5 lbf•ft] using a criss cross pattern and retorque the first screw to ensure proper torque retention.
Install the control
C200
1. Install the adapter (J080) with new O-rings (J090, J095). Tighten the screws (J100) at 47.5 to 61 N•m
[35 to 45 lbf•ft].
2. Install the coupling (J140) onto the shaft.
Wrench size
26 mm 12 pt socket
4 mm internal hex
C300
P109056
Torque
3.5 N•m [2 lbf•ft]
6.5 N•m [4.75 lbf•ft]
AX00000305en-US0101